Table 8-23
Single Motor Modules C type (45 A and 60 A)
Feature
Output data
Rated current (l
)
rated
Intermittent duty current (l
Peak current (l
)
max
Output voltage 3 AC
Output frequency
Apparent power for U
of 600 V
DC
Rated power IEC
3)
Rated power NEC
4)
Input data
DC link voltage (U
)
DC
Overvoltage trip
Undervoltage trip
5)
Electronics power supply
DC link current (I
)
DC link
DC link capacitance
Current-carrying capacity
DC link busbars
24 V DC busbars
Current consumption of the electronics
at 24 V DC
Power loss
Cooling air requirement
Weight
Cable lengths
In the case of overmodulation, a motor output voltage up to 3% higher is possible.
1)
Higher output frequencies up to a maximum of 3200 Hz are possible with an additional license.
2)
Rated power of a typical standard induction motor at 3 AC 400 V according to IEC 60947-4-1:2018 Annex G Table G.1
3)
Rated power of a standard induction motor at 3 AC 460 V according to NEC Table 430.250
4)
Depends on the parameterized device supply voltage
5)
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA
Unit
 
A
) 40 %
A
s6
A
V
Hz
kVA
kW
hp
 
V
V
V
V
A
μF
 
A
A
 
A
W
m
/h
3
kg
m
Article No. 6SL5120-
1UE24-5AC0
 
45
60
90
0 ... 0.707 x DC link voltage
(0 ... 480 V at 680 V DC)
0 ... 550
33
22
30
495 ... 720
380 ... 432
56
1230
 
1
344
64
8.5
See Chapter "Maximum permissible cable lengths (Page 54)"
Motor Modules
8.4 Motor Modules 45 A and 60 A
1UE26-0AC0
 
60
80
120
1)
2)
44
30
40
 
820
24
75
1410
 
200
20
 
1
462
64
8.6
195