Proceed as follows to connect the cores in the connection plug:
1. Starting with W2, V2, U2, insert the cores into the open terminals.
– The cores must be inserted as far as they will go.
– For larger cross-sections, it is helpful if W2, V2, U2 are simultaneously inserted and
2. Tighten the screws. Slotted screwdriver 0.8 x 4.0 mm. Tightening torque: 0.5 - 0.6 Nm
(4.4 lbf in)
8.3.10.5

Wiring the connection plug with push-in connection

Requirement
Electric shock or fire caused by non-certified plug connection plug in the power circuit
Using a non-certified connection plug can result in overheating, fire and/or electric shock.
• Only use certified connection plugs.
Required tools:
• Slotted screwdriver 0.8 x 4.0 mm
Procedure
Table 8-17
6SL3162-2MB00-0AC0
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA
secured by screws.
WARNING
Connection plug with push-in connection
8.3 Motor Modules 3 ... 30 A and 2x3 ... 2x18 A
Terminal
Designation
BR+
Holding brake connec‐
tion
BR-
Motor PE/ground con‐
nection
U2
Motor connection
V2
W2
Motor Modules
Technical data
Spring-loaded terminal with ac‐
tuator
 