Description
Table 8-31
X11: Holding brake connection for Motor Modules 85 A, 132 A and 200 A
X11: Holding brake connection Terminal
Connectable cable cross-sec‐
tions
Stripped length
Screwdriver
It is not permissible that you directly connect conductor BR- to electronics ground M.
1)
8.5.1.6

X12 fan connection

Overview
The interface is located on the lower side of the Motor Module. The fan connection plug is pre-
assembled and premounted on the fan module.
Description
Table 8-32
X12: Fan connection for Motor Modules 85 A, 132 A and 200 A
X12: Fan connection
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA
Designation
+ (BR+)
Connecting the holding brake
- (BR-)
1)
Rigid, flexible
Flexible, with end sleeve without protective col‐
lar
Flexible, with end sleeve with protective collar
AWG / kcmil
8 ... 9 mm (0.31 ... 0.35 inch)
Slotted screwdriver 0.5 x 3.5 mm
Terminal
Designation
1
Fan connection + (red)
2
N/A
3
Fan connection - (black)
4
N/A
5
PWM input (brown)
6
Tacho signal (yellow)
8.5 Motor Modules 85 A, 132 A and 200 A
Technical data
Module output voltage: 24 V DC
Max. load current: 2 A
Minimum load current: 0.1 A
0.08 ... 2.5 mm
2
0.25 ... 2.5 mm
2
0.25 ... 1.5 mm
2
28 ... 12
Technical data
Voltage: 48 V DC
 
Motor Modules