Order Data For The 24 V Terminal Adapter; Connecting The 24 V Busbars - Siemens SINAMICS S220 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S220:
Table of Contents

Advertisement

Mounting
5.5 Connecting the 24 V busbars
5.4.2
Order data for the 24 V terminal adapter
The 24 V terminal adapter can be ordered as replacement part.
X24: 24 V terminal adapter
Article number
6SL3162-2AA00-0AA0
5.5

Connecting the 24 V busbars

5.5.1
Connecting the 24 V busbars
Overview
Die 24 V busbars of components lined up next to one another within a drive line-up are
connected using 24 V connectors. The 24 V connectors are included in the Terminal Kit of the
Motor Modules.
Requirement
Electric shock if the cutout in the protective flap has been broken out
Live parts are exposed if the 24 V connectors are again removed at a later point in time.
Touching live components can result in death or severe injury.
• Replace the protective flap with the broken out cutouts with a new protective flap.
Fire hazard for 24 V connectors and unconnected DC link busbars
For drive lineups in series, whose DC link busbars are not connected with one another, it is not
permissible to insert 24 V connectors between these drive lineups. The 24 V connectors could
otherwise burn and cause severe injury or death as a result of fire or smoke.
• If the DC link busbars of the components are not connected with one another, then you
92
Description
24 V terminal adapter for all Line Modules and Motor Modules in the booksize format
WARNING
WARNING
must ensure that there is a separate 24 V supply for each component using a 24 V terminal
adapter.
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA

Advertisement

Table of Contents
loading

Table of Contents