Siemens SINAMICS S220 Equipment Manual page 245

Booksize power units
Hide thumbs Also See for SINAMICS S220:
Table of Contents

Advertisement

Procedure
Figure 8-88
The fan module is integrated in the motor connection block. Replace the existing fan module
as follows:
1. Open the locking of the cover of the motor connection block left and right and swing it
upwards. Slotted screwdriver 0.8 x 5.5 mm
2. Remove the cores of the motor connection cable. Socket wrench size 13
3. Withdraw the fan connection plug.
4. Remove the two fixing screws of the fan module. T20 torx screwdriver. The protective
conductor of the Motor Module does not have to be removed.
5. Withdraw the fan module out of the Motor Module towards the front.
6. Insert a new fan module into the Motor Module.
7. Cut out the detachable tabs at the motor connection block if required.
8. After the new fan module has been installed, re-connect the Motor Module in the inverse
sequence:
– Insert the fan connection plug into socket X12.
– Screw the fan module into place. T20 torx screwdriver. Tightening torque: 2.2 Nm
– Attach the cores of the motor connection cable and tighten the nuts. Socket wrench
– Close the motor connection block cover.
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA
Fixing screws of the fan module
Fan module
Replacing the fan for Motor Modules 85 A, 132 A and 200 A
(19.5 lbf in)
size 13. Tightening torque: 13 Nm (115 lbf in)
8.5 Motor Modules 85 A, 132 A and 200 A
Motor Modules
243

Advertisement

Table of Contents
loading