Water Connection - Angelo Po 0N1CP1EL User Manual

Pasta cooker
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
WARNING: The connection operations
must be carried out by qualified personnel
with an acknowledged experience in the spe-
cific field, in accordance with the applicable
legislation in the country where the appli-
ance is installed .
The connection must be carried out with due
care and must comply with all applicable reg-
ulatory and legal requirements .
To make the connection, connect the mains
line to the appliance's connection pipe, fitting a
shut-off tap (A), to allow the water supply to be
cut off when necessary. Easily accessible filters
must be fitted downstream of the tap.
WARNING
: The appliance must be
supplied with drinking water having the
characteristics shown in the table .
Parameters to check
Pressure
pH
TDS
Hardness
Index of Langelier (reccomended) (**)
Content of salts and metal ions
Requested
Reccomended (**)
(**) Values different from these parameters may cause corrosion if combined with wrong use and environment.
10

WATER CONNECTION

Chlorine
Chlorides
Sulphates
Iron
Copper
Manganese
HANDLING AND INSTALLATION
A
Value
200÷400 kPa (2÷4 bar)
7÷8.5
40÷150 ppm
3÷9°f (1,5÷5°d, 2.1÷6.3°e, 30÷90 ppm)
>0.5
<0,1 mg/l
<10 mg/l
<30 mg/l
<0,1 mg/l
<0,05 mg/l
<0,05 mg/l
3320040_inst_GB_rev.3