Ams Ez 1000 Converter With Ez108X - Emerson Machinery Health AMS EZ 1000 Operating Manual

Hide thumbs Also See for Machinery Health AMS EZ 1000:
Table of Contents

Advertisement

Operating Manual
MHM-97884
Table 11-4: Additional inaccuracies – DSL
Parameter
Automatic calibration
Multipoint calibration
Extended measuring
range: 2.0 mm
(Extended range factor:
2.0)
Manual calibration
Automatic calibration
Multipoint calibration
Detune 1 / 2
Converter temperature
error at 5 m sensor cable
EZ105x temperature error
at 5 m sensor cable
Converter temperature
error at 10 m sensor cable
EZ105x temperature error
at 10 m sensor cable
11.4.3

AMS EZ 1000 Converter with EZ108x

Accuracy of the standard measuring chain according to API 670 consisting of EZ108x-xx-
xx-010, EZ190x-040, and AMS EZ 1000 Converter with standard target material 42CrMo4
(AISI 4140):
Table 11-5: Accuracy according to API 670
Temperature range
0°C to 45°C (Test range)
EZ 1000
EZ 190x
EZ 108x
1
Measuring range
2
Additional error
MHM-97884, Rev. 1.8
Additional
Measurement
Inaccuracy (DSL),
Test range
1.75%
0.25%
3.75%
3.75%
0.5%
0.75%
-35°C to 65°C (Operating
range)
-35°C to 65°C (Operating
range)
-35°C to 120°C (Operating
range)
(continued)
Additional
Measurement
Inaccuracy (DSL),
Operating range
2.0%
0.5%
4.0%
4.0%
1.0%
1.25%
±2%
-10% to +6%
±1%
-5% to +1%
DSL
1
± 1.25% of MR
12
± 1.0% of MR
1 2
± 1.5% of MR
Technical data
October 2023
Remarks
Only possible with
multipoint calibration
-35 to 85°C at 5 meter
sensor cable
-35 to 180°C at 5 meter
sensor cable
-35 to 85°C at 10 meter
sensor cable
-35 to 180°C at 10 meter
sensor cable
ISF
± 5% of nominal value
± 10% of nominal value
111