Replace An Ams Ez 1000 Converter - Emerson Machinery Health AMS EZ 1000 Operating Manual

Hide thumbs Also See for Machinery Health AMS EZ 1000:
Table of Contents

Advertisement

Maintenance, fault finding, and repair
October 2023
Also, use AMS Machine Studio to get an overview of the converter state. See
for details.
10.3

Replace an AMS EZ 1000 Converter

It is not possible to repair a defective AMS EZ 1000 Converter. In case of defects, the
converters must be replaced. Follow the steps listed below if an AMS EZ 1000 Converter
needs to be replaced.
CAUTION
Any work on the system may impair machine protection.
Procedure
1. Save the AMS EZ 1000 Converter configuration, if possible.
2. Disconnect all wires from the AMS EZ 1000 Converter including sensor and USB
3. Remove the AMS EZ 1000 Converter from the mounting rail.
4. Install the new AMS EZ 1000 Converter.
5. Reconnect all wires including sensor and USB cable.
6. Switch on the power supply.
7. Load the configuration file including the calibration data from the memory of the
102
a) Connect the configuration device (PC/Laptop) through the USB connection
to the AMS EZ 1000 Converter.
b) Switch on the power supply of the converter to be replaced – if not already
done.
c) Start AMS Machine Studio. The software automatically connects to the AMS
EZ 1000 Converter and opens the online view of the converter.
d) Click Configure to open the configuration of the AMS EZ 1000 Converter.
e) Click Reload to load the configuration and the calibration data from the
converter.
f) Save the configuration file including the calibration data. Go to File, and
select Save as.
Note
The data of the Automatic calibration and the Easy calibration (calibration
process without AMS Machine Studio) is saved as Manual calibration data.
g) Go back to the editor and close it.
Do not close AMS Machine Studio.
h) Switch off the power supply.
cable.
The converter will automatically be detected by AMS Machine Studio.
configuration device to the AMS EZ 1000 Converter. If a defect prevents reading the
Operating Manual
MHM-97884
Online View
MHM-97884, Rev. 1.8

Advertisement