Operating Manual
MHM-97884
Table 5-1: Permissible wire cross-section
Wire description
Conductor cross section solid
Conductor cross section flexible
Conductor cross section flexible, with ferrule without
plastic sleeve
Conductor cross section flexible, with ferrule with
plastic sleeve
Conductor cross section AWG
2 conductors with same cross section, solid
2 conductors with same cross section, stranded
2 conductors with same cross section, stranded,
ferrules without plastic sleeve
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve
AWG according to UL/CUL
The required wire stripping length is 10 mm.
Power supply and output signal connection
The AMS EZ 1000 Converter requires a -24 V DC power supply and is typically supplied by
the used measuring amplifiers such as an A6500-UM Universal Measurement Card. Usage
of a suitable external power supply is also possible.
If using an external power supply, ensure that it is a Class 2 power supply or a Limited
Energy source in accordance to CSA 61010-1-12.
Figure 5-12
grounding concept is one possibility. Adapt the grounding concept to the on-site
requirements.
MHM-97884, Rev. 1.8
exemplifies the connection of an AMS EZ 1000 Converter. The shown
Installation and commissioning
Wire cross-section
Minimum
Maximum
0.34 mm²
2.5 mm²
0.2 mm²
2.5 mm²
0.25 mm²
2.5 mm²
0.25 mm²
2.5 mm²
24
12
0.2 mm²
1 mm²
0.2 mm²
1.5 mm²
0.25 mm
1 mm²
0.5 mm²
1.5 mm²
30
12
October 2023
29