Installation and commissioning
November 2022
connector. For further information see sensor connection chapters in the manuals of the
respective protection cards (for example, A6120 or A6500-SR).
CAUTION
To ensure proper measuring function, install the transducer only within the described
mounting angle ranges.
4.3.1
PR 9268/20x-x00 and PR 9268/60x-000 – without
sinking current
The vibration transducers PR 9268/20x-x00 and PR 9268/60x-000 are designed for the
vertical measurement direction (0° position). Without a sinking current, the maximum
admissible deviation from the nominal position is ±30° in positive and negative direction.
See
Figure
Figure 4-12: Deviation of ±30° from the nominal direction
4.3.2
PR 9268/20x-x00 and PR 9268/60x-000 – with sinking
current
The vibration transducers PR 9268/20x-x00 and PR 9268/60x-000 are designed for the
vertical measurement direction (0° position). They can be used with a maximum deviation
of ±60° in positive and in negative direction (related to the nominal direction 0°). See
Figure
26
4-12.
4-13.
Installation Guide
MHM-97479
MHM-97479, Rev. 3.6