Return the server to operation:
3.
a.
b.
c.
d.
e.

Install the Server Top Cover

Place the top cover on the chassis [1].
1.
Latch the top cover closed by pushing down on the button until it is flush with the
2.
cover and you hear an audible click [2].
An audible click indicates that the cover is latched.
Use a Torx T15 screwdriver to turn the release button latch counter-clockwise to
3.
the locked position.

Remove Antistatic Measures

Remove any antistatic straps or conductors from the server chassis.
Otherwise, continue to with this procedure.
Install the server top cover.
See
Install the Server Top
Return the server to the normal rack position.
See
Return the Server to the Normal Rack
Reconnect the power cords and data cables to the server.
Power on the server.
See
Powering On Oracle Database
Verify that the power supply AC OK LED is lit.
Set the cover down so that it hangs over the back of the server by about 1 inch
(25 mm) and the side latches align with the cutouts in the chassis.
Check both sides of the chassis to ensure that the top cover is fully down and
flush with the chassis. If the cover is not fully down and flush with the chassis,
slide the cover towards the back of the chassis to position the cover in the
correct position.
Gently slide the cover toward the front of the chassis. As you slide the cover
toward the front of the server, the release button on the top of the server
automatically rotates downward to the closed position.
Cover.
Position.
Appliance.