Disconnect Cables From the Server

Caution:
The system supplies Standby power to the circuit boards even when the
system is powered off.
Label all cables connected to the server.
1.
Power down the server.
2.
See
Disconnect the power cords from the rear of the server.
3.
Disconnect all data cables from the rear of the server.
4.
If your rackmount kit includes a cable management device, remove the cables
5.
from it.
Depending on the components that you are servicing, either extend the server to
6.
the maintenance position, or remove the server from the rack.

Stabilize the Rack

Caution:
To reduce the risk of personal injury, stabilize the rack cabinet, and extend
the anti-tilt bar before you install the server.
Refer to your rack documentation for detailed instructions for the following steps.
Open and remove the front and back doors from the rack cabinet, only if they
1.
impinge on the mounting bay.
To prevent the rack cabinet from tipping during the installation, fully extend the
2.
rack cabinet anti-tilt bar, which is located at the bottom front of the rack cabinet.
If the rack includes leveling feet beneath the rack cabinet to prevent the rack from
3.
rolling, extend these leveling feet fully downward and lock to the floor.
Related Rack Documentation
Oracle Rack Cabinet 1242 Documentation
Oracle Sun Rack II 1242 Documentation
Powering Down the
Server.
Caution:
When moving the rack cabinet to a new location, verify that the leveling
feet are up before moving the rack.
Preparing the Server for Component Replacement