Page 1
H8/3637 Series FP-80B User System Interface Cable (HS3637ECF61H) for E6000 Emulator User’s Manual ADE-xxx-xxx Rev. 4.0 4/1/03 Renesas Technology Corp. HS3637ECF61HE...
Page 2
1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document.
Page 3
H8/3637 series. The HS3637ECF61H is a user system interface cable that connects an H8/3637series E6000 emulator (HS3L08EPI60H; hereinafter referred to as the emulator) to the IC socket for a FP-80B package for the H8/3637 series MCU on the user system.
Section 1 Configuration...1 Section 2 Connection Procedures ...4 Connecting User System Interface Cable to Emulator Station ... 4 Connecting User System Interface Cable to User System ... 6 2.2.1 Installing IC Socket ... 6 2.2.2 Soldering IC Socket ... 6 2.2.3 Inserting Cable Head ...
Section 1 Configuration Use an IC149-080-012-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80B package IC socket on the user system. Figure 1 shows the configuration of the HS3637ECF61H user system interface cable for the FP-80B package. CAUTION...
Page 6
To emulator station Screws (M2 x 8 mm) with flat washers Socket cover Figure 1 HS3637ECF61H User System Interface Cable Cable body IC socket User system Screws (M2 x 12 mm) with flat washers (for fastening cable head) Cable head...
Page 7
Screws (M2 x 8 mm) Documentation Quantity Remarks Flat cable For the FP-80B package For installing an FP-80B-packaged MCU For fastening cable head (with four flat washers) For installing an FP-80B-packaged MCU (with four flat washers) User’s manual for HS3637ECF61H (this manual)
Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
Page 9
Figure 2 Connecting User System Interface Cable to Emulator Station...
2.2.2 Soldering IC Socket After fastening, solder the IC socket for an FP-80B package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly more solder than the MCU.)
Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-80B package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3.
Page 12
Fasten the user system interface cable head to the IC socket for an FP-80B package on the user system with the four screws (M2 12 mm; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body...
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-80B package (IC149-080-012-B5: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.
Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head...
Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable...
Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Page 18
Pin 1 User system Figure 8 Installing MCU to User System Screws (M2 x 8 mm) with flat washers Socket cover IC socket (IC149-080-012-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.)
Section 4 Verifying Operation 1. When using the H8/3637 series E6000 emulator (HS3L08EPI60H), turn on the emulator according to the procedures described in the H8/3637 Series E6000 Emulator User's Manual (HS3008EPI60HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins.
Page 20
Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications. Ω R1 1 M HCU04 To E6000 emulator HCU04 Ω R2 270 OSC1 OSC2 System clock oscillator Figure 9 System Clock Oscillator and Subclock Input Specifications 0.8 Vcc 0.3 Vcc 55 ns max.
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.
Page 22
The P1 short connector is used for testing. Do not remove the inserted jumper pin. Figure 11 P1 Short Connector...