UM-WI-056
DA16200 DA16600 FreeRTOS Getting Started Guide
The user manual can be f ound in the local f older where the DA16200 DA16600 Evaluation Kit Pro
Power Prof iler.is downloaded.
6.5.3

Current Measurement at Sleep Mode 1

To measure current in Sleep 1, power of f the EVB by setting RTC_PWR_KEY to the OFF position
(SW6 on the DA16200 EVB or SW2 on the DA16600 EVB).
6.5.4

Current Measurement at Sleep Mode 2

To measure current in Sleep 2, use the CLI commands as f ollows.
1. Power on the EVB by setting RTC_PWR_KEY to the ON position (SW6 on the DA16200 EVB or
SW2 on the DA16600 EVB).
2. Type the factory command to set the DA16200/DA16600 to its def ault settings.
3. Af ter the EVB reboots, run the sys.hal command to enter 'hal' mode.
[/DA16200] # sys.hal
4. Run the sleep 2 <time(sec)> command to enter sleep 2 mode f or the specif ied time in
seconds.
[/DA16200/SYS.HAL] # sleep 2 <time(sec)>
For instance, [/DA16200/SYS.HAL] # sleep 2 10
It will make DA16200 stay at sleep 2 f or a set amount of time (10 seconds) and wake up .
6.5.5

Current Measurement at Sleep Mode 3

To measure current in Sleep 3, use the CLI commands as f ollows.
5. Power on the EVK by setting RTC_PWR_KEY to the ON position (SW6 on the DA16200 EVB or
SW2 on the DA16600 EVB).
6. Type the factory command to set the DA16200/DA16600 to its def ault settings.
7. Af ter the EVK reboots, run the sys.hal command to enter 'hal' mode.
[/DA16200] # sys.hal
8. Run the sleep 3 <time(sec)> command to enter sleep 3 mode f or the specif ied time in
seconds.
[/DA16200/SYS.HAL] # sleep 3 <time(sec)>