6. Note and trouble shooting

6.1 About stabilization time for sensor

There is stabilization time for each sensor. It cannot read correct values during the time.
See below the detail of stabilization time of each sensor of table.
Table 1 Sensor Stabilization Time
Sensor Name
ZMOD4410 IAQ
ZMOD4510 OAQ
OB1203
HS3001
ICP
ICM

6.2 Connection issue when using Ethernet (Wired cable)

The Ether PYH only supports the full duplex communication. If your rooter or Ethernet hub only supports half
duplex, it cannot connect the internet. Please use full duplex devices.

6.3 About the trouble of current supply short when using RYZ014A

If the CK-RX65N board is not powered through the Debug port (J14) the current available to the board may
be limited to 100 mA. When using the supplied RYZ014A Pmod module with other code (found here:
RYZ014A - LTE Cat-M1 Cellular IoT Module |
current of 480 mA dependent upon the LTE band, Tx/Rx settings, and network coverage. Please ensure that
the host board can supply sufficient power or provide supplemental USB power via CN4 on the Pmod to
avoid RF instability.

6.4 About when build errors occur

If a 'No such file or directory' error occurs, the project path may be too long. When the path is longer than
256 characters, e² studio outputs errors at build time.
When this error occurs, move the project to a shorter path location (e.g., under C:\).

6.5 About when unable to log in to the Dashboard (Grafana account)

If you cannot log in to the Dashboard with the password you changed in step 6 of 4.2.2 To get the account
10USD of trial of AWS, try the following.
Set "admin" in the Email or username field and set the changed password in the password field.
When changing the password for the initial session, the username is not changed from admin. Therefore,
admin must be entered in the username field. To enable users to log in with your own username and email
address, please change the user information in the Server Admin menu after logging in.
R01QS0064EJ0130 Rev.1.30
June.02.23
When power up first time
Up to 1 Min
Up to 1.5 hours
Up to 20 Min
(After putting figure on sensor, it
may take up to 60 seconds to
sense data)
Up to 30 Sec
Up to 30 Sec
Up to 30 Sec
Renesas) be aware that this Pmod has a maximum operating
Application for AWS - Getting Started Guide
After soft or hard reset
Up to 1 Min
Up to 1 Hours
Up to 20 Sec
(After putting figure on sensor, it
may take up to 60 seconds to
sense data)
Up to 10 seconds
Up to 10 seconds
Up to 10 seconds