Write Error Counters Log Page (02H); Table 72 Write Error Counters Log Page (02H) Page And Parameter Descriptions - Quantum LTO 2 User Manual

Quantum lto 2: user guide
Hide thumbs Also See for LTO 2:
Table of Contents

Advertisement

Write Error Counters Log
Page (02h)
Table 72 Write Error Counters
Log Page (02h) Page and
Parameter Descriptions
LTO-2 SCSI Interface Guide
The Write Error Counters Log Page (02h) records write errors. The
parameters on this page can be reset to 0 with the
2
command.
Page Code
02h
Parameter
Description
0
Errors corrected without substantial delay
1
Errors corrected with possible delay.
2
Total rewrites (sum of Parameter 0003 and
Parameter 0006).
3
Total errors corrected. This is total write
retries less total unrecoverable write errors.
(Parameter 0004 minus Parameter 0006, this
is also the sum of Parameter 0000 and
Parameter 0001.)
4
Total times error correction processed. This
is the total number of write retries.
5
Total bytes processed. This is the total data
sets written.
6
Total uncorrected errors. This is the total
unrecoverable write errors.
Chapter 2 SCSI Commands
LOG SENSE Command
LOG SELECT
Page Length
38h
Length
4
4
4
4
4
4
4
91