Read Error Counters Log
Page (03h)
Table 73 Read Error Counters
Log Page (03h) Page and
Parameter Descriptions
LTO-2 SCSI Interface Guide
The Read Error Counters Log Page records read errors. The parameters
on this page can be reset to 0 with the
2
Page Code
03h
Parameter
Description
0
Errors corrected without substantial delay
1
Errors corrected with possible delay.
2
Total rereads. (Sum of Parameter 0003 and
Parameter 0006)
3
Total errors corrected. This is total read
retries less total unrecoverable errors.
(Parameter 0004 minus Parameter 0006, this
is also the sum of Parameter 0000 and
Parameter 0001)
4
Total times error correction processed. This
is the total number of read retries.
5
Total bytes processed. This is the total data
sets read.
6
Total uncorrected errors. This is the total
unrecoverable read errors.
Chapter 2 SCSI Commands
LOG SENSE Command
command.
LOG SELECT
Page Length
38h
Length
4
4
4
4
4
4
4
92