SCSI Commands: 21BLOG SENSE

3.9.5 Write Error Counters Log Page (02h)

The Write Error Counters Log Page records write errors. The parameters on this
page can be reset to zero with the LOG SELECT command.
Page Code
02h
Parameter
Description
0
Errors corrected without substantial delay
1
Errors corrected with possible delay.
2
Total rewrites. (Sum of Parameter 0003 and Parameter 0006)
3
Total errors corrected. This is total write retries less total unrecoverable write
errors. (Parameter 0004 minus Parameter 0006, this is also the sum of
Parameter 0000 and Parameter 0001)
4
Total times error correction processed. This is the total number of write
retries.
5
Total bytes processed. This is the total data sets written.
6
Total uncorrected errors. This is the total unrecoverable write errors.
Page Length
38h
Page 54
Length
4
4
4
4
4