Figure 4.58 Frer Statistics - Advantech EKI-8500 Series User Manual

Managed tsn switch
Table of Contents

Advertisement

Item
Warning
Latent Error
Statistics
Reset Function
Reset Latent Error
Auto-refresh
Refresh
Clear All
4.4.4.4.2
FRER Statistics
The function provides an overview of the current FRER statistics counters.
1.
Navigate to Monitor > TSN > FRER and click FRER Statistics.
The FRER Statistics page displays.
The following table describes the items in the FRER Statistics page.
Item
Clear
Instance
Mode
Egress Port
Ingress Stream
Out of Order
Roque
Passed
Discarded
Lost
Tagless
Recovery Reset
Latent Error Reset
Generation Reset
Auto-refresh
Refresh
Clear
Description
Displays any operation warnings.
Off: no warning detected
Yellow: warnings detected, use tooltip for further details.
Displays any latent errors
Green: no error detected
Red: latent errors detected
Click to reset the statistics counter.
Click to reset the function.
If this FRER instance is in generation mode, this is used to reset the
sequence number of the sequence generator.
If this FRER instance is in recovery mode, this is used to reset the
recovery function. It resets both possible individual recovery functions
and the compound recovery functions.
Click to clear a sticky latent error.
Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
Click Refresh to refresh the page immediately.
Click Clear All to clear the blocked flags for all entries.

Figure 4.58 FRER Statistics

Description
Click to mark an entry for clearance during the following Clear
operation.
Displays the FRER instance ID.
Displays the operation mode (Generation or Recovery).
Displays the list of egress port numbers.
Displays the list of ingress stream IDs.
Displays the out of order counters.
Displays the receiving roque counters.
Displays the receiving passed counters.
Displays the Receiving discarded counters.
Displays the receiving lost counters.
Displays the receiving tagless counters.
Displays the receiving reset counters.
Displays the receiving latent error counters.
Displays the generation reset counters.
Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
Click Refresh to refresh the page immediately.
Click Clear to clear the counters for the selected port.
80
EKI-8500 Series User Manual

Advertisement