This function allows you to inspect the current PSFP configurations, and possibly
change them as well.
1.
Navigate to Configuration > TSN > PSFP and click Steam Gate.
The PSFP Stream Gate parameters Configuration page displays.

Figure 4.37 PSFP Stream Gate parameters Configuration

The following table describes the items in the PSFP Stream Gate parameters
Configuration page.
Item
Delete
SGI ID
Gate Enabled
Gate States
Cycle Time Value
Cycle Time unit
Cycle Time
Extension
EKI-8500 Series User Manual
Description
Enter a string to indicate the Stream Gate Instance parameter
contains the index of an entry in the Stream Gate Table.
Enter a string to indicate the MaximumSDUSize parameter specifies
the maximum allowed frame size for the stream. Any frame exceeding
this value will be dropped. A value of 0 denote that the
MaximumSDUSize filter is disabled for this stream.
Enter a string to indicate the FlowMeterInstanceID parameter of an
entry in the Flow Meter Table. A value of -1 denotes that no flow meter
is assigned; zero or positive values denote flow meter IDs.
Click to enable or disable (default) the FMI function.
Click to enable or disable (default) the object to indicate whether the
StreamBlockedDueToOversizeFrame function is enabled (TRUE) or
disabled (FALSE).
Click Add New Entry to add Stream Filter entry.
Click Save to save changes.
Click Reset to undo any changes made locally and revert to
previously saved values.
Description
Click Delete to remove the entry. It will be deleted during the next
save.
Enter an string to indicate a parameter for the Stream Gate ID.
Click to enable or disable (default) the Gate Enabled parameter
determines.
Click the drop-down menu to select the administrative value of the
GateStates parameter (options: open, closed).
Enter an string to indicate the administrative value of the cycle time for
the gate. The time may be specified in either milli seconds, micro
seconds or nano seconds as defined by the field Cycle Time unit.
Enter an string to indicate the unit used for specifying the
administrative cycle time (values: ns, us or ms).
Enter an string to indicate the administrative value of the
CycleTimeExtension parameter for the gate (value: unsigned integer
number of nanoseconds).