Figure 4.36 Psfp Stream Filter Configuration - Advantech EKI-8500 Series User Manual

Managed tsn switch
Table of Contents

Advertisement

The following table describes the items in the PSFP Flow Meter Configuration page.
Item
Delete
FMI ID
CIR
CBS
EIR
EBB
CF
CM
Drop on Yellow
Mark RED
Add New Entry
Save
Reset
4.3.5.4.2
Stream Filter
This function allows you to inspect the current PSFP configurations.
1.
Navigate to Configuration > TSN > PSFP and click Steam Filter.
The PSFP Stream Filter Configuration page displays.
The following table describes the items in the PSFP Stream Filter Configuration
page.
Item
Delete
SFI ID
Stream ID
Stream Enable
Priority Spec
Description
Click Delete to remove the entry. It will be deleted during the next
save.
Enter a string to indicate the FlowMeterInstance parameter is an index
into the FlowMeterTable.
Enter a string to indicate the FlowMeterCIR parameter contains an
integer value that represents the CIR value for the flow meter, in bit/s.
Enter a string to indicate the FlowMeterCBS parameter contains an
integer value that represents the CBS value for the flow meter, in
octets.
Additional information required.
Additional information required.
Additional information required.
Additional information required.
Additional information required.
Click to enable or disable (default) the FlowMeterMarkAllFramesRed
parameter contains a Boolean value that indicates whether, if the
MarkAllFramesRed function is enabled, all frames are to be discarded
(TRUE) or not (FALSE).
Click Add New Entry to add Flow Meter entry.
Click Save to save changes.
Click Reset to undo any changes made locally and revert to
previously saved values.

Figure 4.36 PSFP Stream Filter Configuration

Description
Click Delete to remove the entry. It will be deleted during the next
save.
Enter a string to indicate the Stream Filter Instance parameter is an
index into the StreamFilterTable.
The Stream Handle Spec parameter contains a stream identifier
specification value. A value of -1 denotes the wild card value; all
positive values denote stream identifier values.
Click to enable or disable (default) the stream function.
Click the drop-down menu to specify a priority value (value: -1
denotes the wild card value; zero or positive values denote priority).