Wiring A Relay Contact; Figure 2.17 Grounding Connection; Figure 2.18 Terminal Receptor: Relay Contact - Advantech EKI-8500 Series User Manual

Managed tsn switch
Table of Contents

Advertisement

Caution! Do not block air ventilation holes.
Electromagnetic Interference (EMI) affects the transmission performance of a device.
By properly grounding the device to earth ground through a drain wire, you can setup
the best possible noise immunity and emissions.
Connection to
Grounding Point
By connecting the ground terminal by drain wire to earth ground the switch and chas-
sis can be ground.
Note!
Before applying power to the grounded switch, it is advisable to use a
volt meter to ensure there is no voltage difference between the power
supply's negative output terminal and the grounding point on the switch.
2.7.4

Wiring a Relay Contact

The following section details the wiring of the relay output. The terminal block is wired
and then installed onto the terminal receptor.
The terminal receptor includes a total of six pins: two for PWR1, two for PWR2 and
two for a fault circuit.
EKI-8500 Series User Manual
Drain Wire with Lug

Figure 2.17 Grounding Connection

V2+V2-
1A@24V
PWR2
P-Fail

Figure 2.18 Terminal Receptor: Relay Contact

21
V1+V1-
DC12-48V
PWR1

Advertisement

Table of Contents
loading

This manual is also suitable for: