Removing And Installing The Front Fixed Fan; Removing The Front Fixed Fan; Figure 63. Installing The Rear Fixed Fan - Intel P4000S Series Service Manual

Server chassis
Table of Contents

Advertisement

6.
Connect fan power cable to the server/workstation board. See the Quick Start User's Guide or
Service Guide provided with your Intel server/workstation board for appropriate connection location.

Removing and Installing the Front Fixed Fan

NOTE
This procedure applies only to the Intel
P4304XXSHDR, P4304XXSFDN, and P4304XXSHDN.

Removing the Front Fixed Fan

1.
Observe the safety and ESD precautions at the beginning of this book.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
Remove the chassis cover. For instructions, see "Removing the Chassis Cover".
3.
Remove the airduct if it is installed. For instructions, see "Removing the Airduct".
4.
5.
Disconnect the appropriate fan power cable from the server board.
6.
Remove the two screws which secured the fan assembly, and take the fan assembly out (see letter
A).
7.
Locate the four nylon rivets on the four corners of the fan assembly. Remove all the four nylon rivets
from the rear vent cover to take the fan out (see letter B and C).
®
Intel
Server Chassis P4000S Service Guide

Figure 63. Installing the Rear Fixed Fan

®
Server chassis P4304XXSFEN, P4304XXSHEN, P4304XXSFDR,
Hardware Installations and Upgrades
43