Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel Order Number D37596-004...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit CD and/or at http://support.intel.com/support/...
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
/support.intel.com/support/motherboards/server/chassis/sc5299-e/. Manual Organization ® Chapter 1 provides a brief overview of the Intel Entry Server Chassis SC5299-E. In this chapter, you will find a list of the server chassis features, photos of the product, and product diagrams to help you identify components and their locations.
Front panel, installed in the chassis • Attention document, in the chassis product box • Intel® Entry Server Chassis SC5299-E Quick Start User's Guide, in the chassis product box • Four M3 screws for installing 5.25-in drive component, in the hardware kit •...
Page 7
To make sure your system Power Budget Tool at falls within the allowed http://support.intel.com/support/motherboards/server/chassis/ power budget sc5299-e Intel ® System Management Software For software to manage ® your Intel server Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 8
Preface viii Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Removing the Processor Air Duct ................19 Installing the Processor Air Duct .................20 Installing or Removing a Server Board ................20 Installing and Removing a Fixed Hard Drive ...............26 Installing a Fixed Hard Drive ..................26 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 10
Safety Warnings and Cautions ..................97 Intended Application Uses ..................98 Site Selection ......................98 Equipment Handling Practices ..................98 Power and Electrical Warnings ................... 98 System Access Warnings ................... 99 Rack Mount Warnings ....................100 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 11
World Wide Web ........................ 137 Telephone ..........................137 U.S. and Canada .......................137 Europe ........................137 In Asia-Pacific region ....................138 Japan ........................138 Latin America ......................138 ® D. Intel Server Issue Report Form ..............141 E. Warranty ......................145 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 12
Limited Warranty for Intel® Chassis Subassembly Products ..........145 Extent of Limited Warranty ....................145 Warranty Limitations and Exclusions ................146 Limitations of Liability ....................146 How to Obtain Warranty Service ..................146 Telephone Support ....................147 Returning a Defective Product .................. 147 F.
Page 13
Figure 37. Removing Fixed Hard Drive from Drive Bay ............34 Figure 38. Re-installing Drive Cage EMI Shield ............... 34 Figure 39. Removing 5.25-in Drive EMI Shield (DP/WS/BRP configuration shown)....35 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide xiii...
Page 14
Figure 81. Attaching Filler Panel to Hot Swap Drive Cage ............65 Figure 82. Removing Thumb Screws from Backplane............. 65 Figure 83. Attaching Fan Bracket to Hot Swap Drive Cage (SAS/SATA drive cage illustrated).. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 15
Figure 114. Attaching Inner Rack Rails to Chassis (DP/WS/BRP configuration shown) ..89 Figure 115. Attaching Outer Rack Rails to Rack Uprights ............90 Figure 116. Installing Chassis into Rack .................. 91 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 16
Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 17
Table 6. 670-W Power Supply Output Capability ..............94 Table 7. 650-W Power Supply Output Capability ..............95 Table 8. System Environmental Specifications ................ 95 Table 9. Product Regulatory Compliance Markings ............... 151 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide xvii...
Page 18
Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Server Chassis Features ® This chapter describes the main features of the Intel Entry Server Chassis SC5299-E. The location of important chassis components and connections, as well as a description of LED identification, are also presented. AF000307 ® Figure 1. Front View of Intel Entry Server Chassis SC5299-E ®...
Server Chassis Features NOTES: 1. For updated server board support, go to http://support.intel.com/support/motherboards/server/ chassis/sc5299-e/. ® Table 2 summarizes the features of the Intel Entry Server Chassis SC5299-E. Table 2. Server Chassis Features Feature Description • Dimensions (pedestal) 17.8 in (45.2 cm) high with feet; 17.6 in (44.7 cm) without feet •...
Front View Components TP02345 A. 5.25-in Device Drive Bays B. Front Panel C. Drive Bay Access Door D. Door Lock E. Front Panel USB Ports Figure 2. Front View Components (with Front Bezel Assembly) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
A. 5.25-in Device Drive Bays B. 3.5-in Device Drive Bay C. Hard Drive Cage D. Drive Bay EMI Shield (shown open) E. Front Panel USB Ports Figure 3. Front View Components (without Front Bezel Assembly) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
H. Fixed Hard Drive Cage I. Large Processor Air Duct J. Rear Tool-less PCI Retention Mechanisms K. Fan Duct / System Fan Assembly L. Power Supply Figure 4. Internal Components (DP/WS/BRP Configuration) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
F. PCI Add-in Card Guide G. Front Panel USB Ports H. Fixed Hard Drive Cage I. Rear Tool-less PCI Retention Mechanisms J. System Fan K. Power Supply Figure 5. Internal Components (UP Configuration) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
F. Alternate Serial B port knockout G. PCI Add-in Card slots H. PCI Tool-less Card Retention Mechanisms I. External SCSI knockout J. Serial B port knockout Figure 6. Back Panel Components Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Blinking amber indicates a power fault, fan fault, or a non-critical temperature or voltage fault. No light indicates a fatal error during POST. NOTES: 1. LED status may vary depending on server board integrated. Figure 7. Front Panel Components Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
SCSI, SATA or SAS hard drives) may be purchased to replace the fixed hard drive cage. See Table 3 for order code information. For instructions on installing hard drives, see “Installing and Removing a Fixed Hard Drive”. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Entry Server Chassis SC5299-E can be optionally mounted into a rack. Instructions for installing your chassis into a rack are included with the rail kit. The order number for the rack mounting kit is APP3RACKIT. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Table 3. Accessories and Order Codes Accessory Order Code SAS/SATA Hot Swap Drive Bay Upgrade Kit AXX6SASDB SCSI Hot Swap Drive Bay Upgrade Kit AXX6SCSIDB Hot Swap Conversion Kit APP3HSDBKIT Rack Mount Kit APP3RACKIT Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 30
Server Chassis Features Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2. Turn off all peripheral devices connected to the server. Turn off the server. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
1. Slide the left side cover on the chassis and latch securely (see letter “A” in the following figure). 2. (Optional) Replace screws (see letter “B”). TP00831 Figure 11. Installing Left Side Cover Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
5. Remove the two screws (see letter “A” in the following figure”) securing the right side cover to the chassis. Lift the right side cover off the chassis. TP01736 Figure 12. Removing Right Side Cover from Chassis Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
“Installing the Front Bezel Assembly”. 3. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover” 4. Reconnect all peripheral devices and the AC power cable. Power up the server. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
“B”). Disengage the three clips that attach the right side of the front bezel assembly to the chassis and remove (see letter “C”). TP02034 Figure 14. Removing Front Bezel Assembly (DP/WS/BRP configuration shown) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 15. Installing the Front Bezel Assembly (DP/WS/BRP configuration shown) 2. Reinstall the left side cover. For instructions, see “Installing the Left Side Cover”. 3. Reconnect all peripheral devices and the AC power cable. Power up the server. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Removing the Processor Air Duct ® Note: The following procedure is not applicable to the UP configuration of the Intel Entry Server Chassis SC5299-E. The processor air duct on the UP configuration is built into the left side cover.
Hardware Installations and Upgrades Installing the Processor Air Duct ® Note: The following procedure is not applicable to the UP configuration of the Intel Entry Server Chassis SC5299-E. The processor air duct on the UP configuration is built into the left side cover.
6. Disconnect cables from any installed fixed hard drives. If necessary, remove hard drives from fixed hard drive cage. For instructions on removing fixed hard drives, see “Removing a Fixed Hard Drive”. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
9. Remove the PCI card guide by pressing in on the blue tabs (see letter “A” in the following figure) and pulling the PCI card guide outward (see letter “B”). TP01732 Figure 20. Removing PCI Card Guide Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Hardware Installations and Upgrades 10. (For all server boards on DP/WS/BRP configurations EXCEPT for Intel® Server Board S3000AH) Remove the processor air duct. For instructions, see “Removing the Processor Air Duct”. ® 11. If installing a server board, refer to your Intel Server Board User’s Guide and/or...
Figure 22. Inserting Fixed Hard Drive Cage into Chassis (DP/WS/BRP configuration only) 15. If previously removed, install fixed hard drives and connect power and data cables. For instructions, see “Installing a Fixed Hard Drive”. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
18. Re-install the left side cover. For instructions, see “Installing the Left Side Cover” 19. Plug all peripheral devices and the AC power cable(s) back into the server. Power up the server. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 24. Drive Bay Slot Order 1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
TP01869 Figure 25. Removing Drive Cage EMI Shield from Chassis (DP/WS/BRP configuration shown) 6. Remove any PCI add-in boards that use the PCI card guide. For instructions, see “Removing PCI Add-in Boards”. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
8. Route the required power cables (connectors P8-P13) from behind the PCI card guide through the cable routing area at the bottom of the fixed drive cage. AF000317 Figure 27. Routing Hard Drive Power Cables Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
10. Insert fixed hard drive into drive bay and push until it stops. Ensure that the power and data connector end of the hard drive is facing forward AF000319 Figure 29. Inserting Hard Drive into Drive Cage Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
12. Install additional drives as necessary. Warning: Drive bay slots 1, 3, and 5 MUST be populated first. Failure to do so could result in thermal issues within the chassis. AF000316 Figure 31. Drive Bay Slot Order Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
AF000429 Figure 32. Cabling a Fixed Hard Drive 14. Re-attach the drive cage EMI shield to the chassis and tighten the thumb screw. AF000315 Figure 33. Re-installing Drive Cage EMI Shield Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”. 4. Remove the front bezel assembly. For instructions, see “Removing and Installing the Front Bezel Assembly”. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
6. Disconnect the data and power cables from the hard drive to be removed (see letter “A” in the following figure). Pull the drive latch forward (see letter “B”) to unlatch the drive locking mechanism for the hard drive you want to remove. AF000430 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 37. Removing Fixed Hard Drive from Drive Bay 8. Re-attach the drive cage EMI shield to the chassis and tighten the thumb screw. AF000315 Figure 38. Re-installing Drive Cage EMI Shield Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
5. Remove the EMI shield from the 5.25-in device drive bay (see letter “A” in the following figure). Move latch to the “unlock” position (see letter “B”). TP01063 Figure 39. Removing 5.25-in Drive EMI Shield (DP/WS/BRP configuration shown) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
P4 connector from the power supply) and data cables to the rear of the CD-ROM or DVD-ROM drive (see letter “F”). TP01064 Figure 40. Installing CD-ROM or DVD-ROM Drive (DP/WS/BRP configuration shown) 7. If necessary, remove the filler panel from the front bezel assembly. TP01723 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
(see letter “A” in the following figure). Move latch to the “unlock” position (see letter “B”). Slide CD-ROM or DVD-ROM drive out of the Device Drive Bay (see letter “C”). TP02047 Figure 41. Removing CD-ROM or DVD-ROM Drive (DP/WS/BRP configuration shown) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Note: You may want to install an operating system before installing any PCI add-in boards. 1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Place board on an anti-static surface. Record the type and serial number of the add-in board in your equipment log. Set jumpers or switches on the board according to the manufacturer’s instructions. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Appendix A, “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
(see letter “A” in the following figure). Place the removed add-in board in an anti-static protective wrapper. Close the back panel PCI Add-in Card Retention Device (see letter “B”). TP01724 Figure 47. Removing PCI Add-in Board Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
3. Remove the left side cover. For instructions, see “Removing the Left Side Cover” 4. Remove the front bezel assembly if it is installed. For instructions, see “Removing the Front Bezel Assembly”. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Lift the right side cover off the chassis. TP01736 Figure 49. Removing Right Side Cover from Chassis 6. Remove the three screws securing the front panel board to the chassis. TP01737 Figure 50. Unattaching Front Panel Board from Chassis Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
“B”) and the chassis intrusion cable (see letter “C”) from the front panel board. AF000432 Figure 51. Removing Front Panel Board from Chassis 8. Remove standoffs from old front panel and install on new front panel. TP02000 Figure 52. Removing Standoffs from Front Panel Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
10. Use one hand to align the front panel board in position inside the chassis. With your other hand, tighten the three screws to secure the front panel board to the front of the chassis. TP01740 Figure 54. Positioning Front Panel Board in Chassis Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Appendix A, “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Hardware Installations and Upgrades 4. (For all server boards on DP/WS/BRP configuration EXCEPT Intel® Server Board S3000AH) Remove the fan duct /system fan assembly. AF000284 Figure 56. Removing Fan Duct / System Fan Assembly (DP/WS/BRP configuration) 5. (For UP configuration and Intel® Server Board S3000AH on DP/BRP configuration) Disconnect the fan power cable from the server board (see letter “A”...
Hardware Installations and Upgrades 6. (For UP configuration and Intel® Server Board S3000AH on DP/BRP configuration) Install the new system fan in the snap-in bracket. TP01712 Figure 58. Installing System Fan in Chassis (UP configuration) 7. (For all server boards on DP/WS/BRP configuration EXCEPT Intel® Server Board S3000AH) Re-install the fan duct / system fan assembly.
® Caution: The fixed power supply is NOT hot swappable in the UP, DP and WS models of the Intel Entry Server Chassis SC5299-E. Before removing or replacing the fixed power supply,...
Make sure that the new fixed power supply rests on the small metal shelf on the side wall of the chassis (see letter “A” in the following figure). TP01753 Figure 62. Inserting Fixed Power Supply in Chassis Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 63. Locking Fixed Power Supply into Chassis ® 9. Route and connect the P1, P2, and P14 cables to the server board. Refer to the Intel ® Server Board Quick Start User’s Guide or User Guide that came with your Intel server board for appropriate power connections.
Note: For Intel® Server Board S3000AH with SC5299BRP configuration only: Although a redundant power supply may be added to the SC5299BRP chassis, the Intel® Server Board S3000AH does not have a power supply failure detection mechanism in place to support it.
Figure 66. Removing Hot Swap Power Supply Module from Chassis 4. Insert new hot swap power supply module. TP00854 Figure 67. Inserting Hot Swap Power Supply Module in Chassis 5. Connect power cable to replaced hot swap power supply. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 68. Removing Hot Swap Power Supply Module 5. Remove second (redundant) hot swap power supply module (or filler panel), if one is present. 6. Disconnect all internal power cables from chassis components and server board. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Note: You may have to work the power cables through slot sopenings with your free hand as you remove the power supply cage from the chassis. TP01762 Figure 70. Detaching Hot Swap Power Supply Cage from Rear of Chassis Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
10. Attach the rear support bracket to the new power supply cage with the two screws removed from the previous step. TP01763 Figure 72. Attaching Rear Support Bracket to Power Supply Cage Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 73. Securing Hot Swap Power Supply Cage to Rear of Chassis 12. Secure inside panel of hot swap power supply cage to chassis with two screws. TP01767 Figure 74. Securing Hot Swap Power Supply Cage to Inside of Chassis Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 75. Re-installing Hot Swap Power Supply Module(s) 18. Install the left side cover. For instructions, see “Installing the Left Side Cover”. 19. Reconnect all peripheral devices and the AC power cable(s) to the server. Power up the server. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Hardware Installations and Upgrades Installing Feet for a Pedestal-configured Chassis ® Note: Do not install feet on your Intel Entry Server Chassis SC5299-E if it is to be installed in a rack. Only install feet on a pedestal-configured chassis. 1. Observe the safety and ESD precautions listed in Appendix A, “Safety...
Page 78
Hardware Installations and Upgrades Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
The fixed hard drive cage that ships with your Intel Entry Server Chassis SC5299-E is upgradeable to a hot swap drive cage with a SCSI or SAS/SATA backplane. See your Intel Representative for ordering information. Up to six hot swap hard drives can be installed in the optional hot swap drive cage. Power requirements for each individual hard drive may limit the maximum number of drives that can be integrated into the server chassis.
BRP configuration shown) 6. Disconnect cables from any fixed hard drives and remove hard drives from fixed hard drive cage. For instructions on removing fixed hard drives, see “Removing a Fixed Hard Drive”. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
8. Gather together the components for the hot swap drive cage installation. You should have a hot swap drive cage with either a SAS/SATA or SCSI backplane, a side filler panel, a latch plate, a fan bracket, and a fan. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 79. Removing Stud Screws from Hot Swap Drive Cage 10. Attach the latch plate to the left side of the hot swap drive cage. TP01060 Figure 80. Attaching Latch Plate to Hot Swap Drive Cage Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 81. Attaching Filler Panel to Hot Swap Drive Cage 12. Remove the two thumb screws that secure the backplane to the hot swap drive cage. TP01716 Figure 82. Removing Thumb Screws from Backplane Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
The backplane may have slipped once the thumb screws were removed. Ensure that the backplane is positioned correctly before re-tightening the thumb screws. TP01061 Figure 83. Attaching Fan Bracket to Hot Swap Drive Cage (SAS/SATA drive cage illustrated) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Press the fan into the fan bracket until is clicks into place. Caution: Ensure that the label and directional airflow arrow on fan are pointed out (away from the backplane). TP01062 Figure 84. Attaching Fan to Fan Bracket Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Figure 85. Inserting Hot Swap Drive Cage into Chassis (DP/WS/BRP configuration shown) 16. Connect fan cable to the appropriate connector on the server board. See your server board documentation for information on the location of the fan cable connector. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
(Optional, dependent on server board installed) Connect the IPMB header (see letter “C”) to the IPMB connector on the SCSI backplane. iv. Connect the fan power to the server board. For the Intel® Server Board S5000VSA, use FAN1. For other Intel® server boards, refer to the Quick Start User’s Guide that came with the server board.
HDD 2 HDD 5 HDD 0 HDD 4 AF00450 Power cable Data Cable IPMB SES (not available in AXX6DRV3GEXP) Figure 87. Layout of Cable Connectors on the SAS/SATA Backplane (Backplane without expander shown) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Connect the IPMB cable (see letter “C”). iv. Connect the SES cable (see letter “D”). v. Connect the fan power to the server board. For the Intel® Server Board S5000VSA, use FAN1. For other Intel® server boards, refer to the Quick Start User’s Guide that came with the server board.
SATA connector on the SAS/SATA backplane. iii. Connect the IPMB cable (see letter “C”). iv. Connect the fan power to the server board. For the Intel® Server Board S5000VSA, use FAN1. For other Intel® server boards, refer to the Quick Start User’s Guide that came with the server board.
Entry Server Chassis SC5299-E does not support all hard drives. See “Additional Information and Software”for an Internet link to a list of supported hard drives. 1. Open the drive bay access door. AF000311 Figure 90. Opening Drive Bay Access Door Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
5. Set any jumpers and/or switches on the drive according to the drive manufacturer's instructions. 6. With the drive circuit-side down, position the connector end of the drive so that it is facing the rear of the drive carrier. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Once the black drive carrier lever begins to close by itself, push on it to lock the drive carrier into place. AF000313 Figure 94. Re-installing Drive Carrier in Hot Swap Drive Cage Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
9. Close the drive bay access door. AF000314 Figure 95. Closing Drive Bay Access Door Removing a Hot-swap Hard Drive 1. Open the drive bay access door. AF000311 Figure 96. Opening Drive Bay Access Door Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
3. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive from the carrier. Store the old drive in an anti-static bag. TP01714 Figure 98. Removing Hard Drive from Drive Carrier Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
The green latch must be to the left. Do not push on the black lever until the lever begins to close by itself. When the black lever begins to close by itself, push on it to lock the drive carrier into place. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Note: For proper airflow, the drive carrier must be replaced in the chassis, even if no hard drive is installed in it. AF000313 Figure 101. Re-installing Drive Carrier in Hot Swap Drive Cage 6. Close the drive bay access door. AF000314 Figure 102. Closing Drive Bay Access Door Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 98
Hot Swap Drive Cage Upgrade Install Instructions (optional) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Lay the chassis down on its right side. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
5. Remove the top side cover by pressing the latch and pushing back on the side cover to slide rearward and lift from chassis. TP00958 Figure 104. Removing Top Side Cover from Chassis Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
6. Remove any PCI add-in boards. Remove the PCI card guide by pressing in on the blue tabs (see letter “A” in the following figure) and pulling the PCI card guide outward (see letter “B”). TP02001 Figure 105. Removing PCI Card Guide Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
7. Remove plastic filler panel from chassis by pushing on interior tab (see letter “A” in the following figure) and sliding filler panel towards rear of chassis (see letter “B”). AF000285 Figure 106. Removing Plastic Filler Panel from Chassis (DP/WS/BRP configuration shown) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
8. Remove the three plastic plugs from left side of chassis. AF000286 Figure 107. Removing Plastic Plugs (DP/WS/BRP configuration shown) 9. Remove two screws from left and right sides of chassis. AF000287 Figure 108. Removing Rear Screws (DP/WS/BRP configuration shown) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
TP02004 Figure 109. Removing Plastic Plugs from Top Side Cover 11. Install rack handle on left side cover using four 6-32 screws. TP01053 Figure 110. Installing Rack Handle on Left Side Cover Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
13. Install top side cover on chassis. Warning: This chassis must be operated with the left side cover installed to ensure proper cooling. TP01057 Figure 112. Installing Top Side Cover on Chassis Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
16. Attach outer rack rails to rack uprights. Ensure that the screws (two per outer rack rail; see letter “A” in the following figure) pass through the rack upright (see letter “B”), and the outer rack rail (see letter “C”). Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
WARNING: Safe handling of this system requires TWO people. TP01058 Figure 116. Installing Chassis into Rack 18. Reconnect all peripheral devices and the AC power cable to the server. Power up the server. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 110
Rack Mount Kit Install Instructions (optional) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
"Calculating Power Usage." Table 4. 420-W Power Supply Output Capability Maximum Voltage Current +3.3 V 17 A +5.0 V 20 A +5 V Standby 20 A +12.0 30 A -12.0 V 0.5 A Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
+3.3 V 24 A +5.0 V 30 A +5 V Standby 3.0 A +12 V1 16 A +12 V2 16 A +12 V3 16 A +12 V4 16 A -12.0 V 0.5 A Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Safety Information Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel®...
Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen. Vorsicht: Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es nicht ohne diese Abdeckung betrieben werden. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant...
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Attention: Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ventilateur, ne mettez pas le système en route sans la protection en place. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Utilisez si possible un tapi de mousse conducteru, mais pas l’emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Safety Information Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de ® Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento...
Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio de la tarjeta. No deslice la tarjeta sobre ninguna superficie. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 137
Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 144
• Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 146
Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 147
Telekommunikationsleitungen mit dem Modem bestehen; • "mit einer geerdeten Wechselstromsteckdose ausgerüstet sein; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 149
• "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 151
"Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 153
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 154
Installation/Assembly Safety Instructions Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out an “Intel®...
Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 157
Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 158
Getting Help Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Revision Address Revision Low-profile Riser PCI Slot 1 PCI Slot 2 PCI Slot 3 Full-height Riser PCI Slot 1 PCI Slot 2 PCI Slot 3 Video On-board Video Add-in Video On-Board NIC1 Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 161
On-board Platform Instrumentation only ____________________________________ ® Intel Management Module - Professional Edition____________________________ ® Intel Management Module - Advanced Edition _____________________________ Control Panel Information Standard Control Panel _________________________________________________ ® Intel Local Control Panel_______________________________________________ Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Page 162
Please also include any details on troubleshooting already done. ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
"as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 166
Warranty Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
(or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
This server chassis has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative.
Table 9. Product Regulatory Compliance Markings Regulatory Region Marking Compliance cULus Listing Marks USA/Canada GS Mark Germany CE Mark Europe FCC Marking (Class A) EMC Marking (Class A) Canada VCCI Marking (Class A) Japan Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
This product has been tested in accordance to, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance. VCCI (Japan) Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Interchanging or use of other components will void the UL listing and other product certifications and approvals. Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder...
Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an approved/pending RoHS exemption applies.
Page 174
Regulatory and Compliance Information Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide...
Need help?
Do you have a question about the S3210SHLC - Entry Server Board Motherboard and is the answer not in the manual?
Questions and answers