Station No./IP Address Settings

Set the station No. and IP address of the own station of the Motion module.
Item
Station No.
IP Address
Subnet Mask
Default Gateway
2 PARAMETER SETTINGS
98
2.2 Required Settings
Description
The station No. of the master station is fixed to 0.
Set the IP address of the own station.
Set an IP address different from those used in other stations. (Page 74 IP address
duplication detection)
Do not set the following values.
• The third and fourth octets are all 0 or all 1.
• The host address bits are all 0 or all 1
• Reserved address
Set the subnet mask.
Set the same value for the master station and device station.
If the subnet mask is empty, the address class (class A, class B, class C) is determined from the
setting of "IP Address", and operation is done with the subnet mask according to the address
class.
The subnet mask for each class is as follows.
• Class A: 255.0.0.0
• Class B: 255.255.0.0
• Class C: 255.255.255.0
The IP address for each class is as follows.
• Class A: 0.x.x.x to 127.x.x.x
• Class B: 128.x.x.x to 191.x.x.x
• Class C: 192.x.x.x to 223.x.x.x
The host address for each class is the 0 section shown below.
• Class A: 255.0.0.0
• Class B: 255.255.0.0
• Class C: 255.255.255.0
Set the default gateway.
Setting range
0.0.0.1 to 223.255.255.254
(Default: 192.168.3.253)
• Empty
• 0.0.0.1 to 255.255.255.255
(Default: empty)
• Empty
• 0.0.0.1 to 223.255.255.254
(Default: empty)