Mitsubishi Electric MELSEC iQ-R Series User Manual page 124

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Item
Target Module Information
Method selection
Parameter
[Clear All "Read Value"] button
Information
[Clear All "Write Value/Setting Value"]
button
Processing option
[Import] button
[Export] button
Procedure for clearing a saved parameter
When returning the saved parameters of a not-required device station to the not-set status, perform the following procedure.
1.
If the saved parameters are to be saved, output them in a CSV file using the [Export] button.
2.
Delete not-required device stations from the list of stations.
3.
Select the same module as the deleted device station in "Module List", and drag it to the list of stations or the network
map.
Conditions for clearing a saved parameter
Saved parameters of a device station can be cleared under the following conditions.
When saved parameters are cleared, execute "Parameter auto-setting" or "Parameter read" in the "Parameter of Device
Station" window and read the parameters of the device station.
Item
"CC-Link IE TSN
Configuration" window
"Parameter of Device
Station" window
Module Parameter
System Parameter
Module Configuration
Navigation window
Read from PLC
Navigation window
MELSOFT Navigator
2 PARAMETER SETTINGS
122
2.5 "CC-Link IE TSN Configuration" Window
Operation
Open the "CC-Link IE TSN Configuration" window.
Reflect setting and close the window.
Execute detection of connected/disconnected devices.
Change the function version in the "Properties" window.
Open the "Parameter of Device Station" window.
Manually delete "Network Configuration Settings" to apply.
Change "Station Type" or set parameters that do not exist.
Divert system parameters from another project.
Delete a module and check.
Delete a module.
Read module parameters that have a different network
configuration and the same start I/O No..
Import the data of a Motion module to take network
settings.
Reflect the parameter.
Description
Information for the selected device stations is displayed.
Select processing to be executed for selected device stations.
• Parameter auto-setting: Automatically set contents of "Write Value/Setting Value" to the
device station. ( Page 91 Device station parameter automatic setting)
• Parameter read: Read parameters from the selected device station.
• Parameter write: Write parameters to the selected device station.
Click to clear all setting details that were read using "Parameter read".
Click to clear all setting details that are written using "Parameter write".
When there are options for processing selected by "Method Selection", setting items are
displayed.
Read contents of parameter processing created in a CSV file.
Output contents of parameter processing set in this window to a CSV file.
Description
When there is no device station with a station No. that matches the
saved parameter information in the "CC-Link IE TSN Configuration"
window, saved parameters of the relevant device station are
skipped.
Skipped parameters of the device station are cleared.
Saved parameters of a device station that is not in the actual
system configuration are cleared.
All saved parameters are cleared.
When the "Properties" window is closed, saved parameters are
cleared.
Saved parameters that mismatch the relevant device station are
skipped.
Clicking the [Close with Reflecting the Setting] button in the above
state clears the skipped saved parameters.
Parameters of "Network Configuration Settings" return to default.
Parameters of the device station are not diverted.
Parameters are deleted together with the module.
Parameters are overwritten.
Saved parameters are cleared.