Module Change - Mitsubishi Electric MELSEC iQ-R Series User Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Module change

The following shows how to replace the general-purpose CC-Link IE TSN module with a device station and how to change a
device station to the general-purpose CC-Link IE TSN module.
Replacement of the general-purpose CC-Link IE TSN module
Replace the general-purpose CC-Link IE TSN module with a device station.
Right-click a general-purpose CC-Link IE TSN module in the station list on the "CC-Link IE TSN Configuration" window
 click [Change Module]  [Replace General CC-Link IE TSN Module].
Replacement
target list
Replacement
candidate list
Item
Replacement
Station Type
Target
Replacement target list
[Select All] button
[Cancel All Selections] button
Replacement
Refine Type
Candidate
Search String
[Search] button
Replacement candidate list
Outline Specification
Replace the object name of
replacement target module to the
model name selected in
replacement candidate
[Replace] button
[Cancel] button
Changing a device station
Change a device station to a general-purpose CC-Link IE TSN module with the same station type.
Right-click a device station in the station list on the "CC-Link IE TSN Configuration" window  click [Change Module] 
[Change to General CC-Link IE TSN Module].
Description
The station type of the general-purpose CC-Link IE TSN module selected in the station list on the "CC-
Link IE TSN Configuration" window is displayed.
The general-purpose CC-Link IE TSN modules whose station type is the same as the one selected in the
station list on the "CC-Link IE TSN Configuration" window are displayed.
By selecting the checkboxes, multiple general-purpose CC-Link IE TSN modules can be replaced.
Selects all the checkboxes in the replacement target list.
Deselects all the checkboxes in the replacement target list.
Filters the replacement candidate list by type.
Searches the input string with the model name and outline specification.
Displays the replacement candidate list with the conditions set in "Refine Type" and "Search String".
Displays the replaceable modules.
Displays the outline specification of the module selected in the replacement candidate list.
Selecting this checkbox replaces the object name of the replacement target module with the model name
of the module selected as the replacement candidate.
Replaces the module selected in the replacement target list with the one selected in the replacement
candidate list.
Stops the replacement processing and closes the window.
2 PARAMETER SETTINGS
2.5 "CC-Link IE TSN Configuration" Window
2
127