■ MELSOFT transmission port (TCP/IP) continuous unlock failure count (Un\G3708802)
The mismatch count of remote password at unlock of the MELSOFT transmission port (TCP/IP) is stored. The count is
cleared when the password matches.
Range: 0 to 65535 (Values of 65535 or more are not changed)
■ SLMP transmission port (UDP/IP) continuous unlock failure count (Un\G3708805)
The mismatch count of remote password at unlock of the SLMP transmission port (UDP/IP) is stored. The count is cleared
when the password matches.
Range: 0 to 65535 (Values of 65535 or more are not changed)
■ SLMP transmission port (TCP/IP) continuous unlock failure count (Un\G3708806)
The mismatch count of remote password at unlock of the SLMP transmission port (TCP/IP) is stored. The count is cleared
when the password matches.
Range: 0 to 65535 (Values of 65535 or more are not changed)
Network type information area (Network type information)
■ Network type information area (Network type information) (Un\G3762687)
5: CC-Link IE TSN
Ethernet P1/2 common information
■ Initial status (Un\G7891480)
The initial processing status of the Ethernet connection is stored.
[b0]: Initial normal completion status
• 1: Initialization normal completion
• 0: 
[b1]: Initial abnormal completion status
• 1: Initialization abnormal completion
• 0: 
[b2 to b15]: Not used (Use prohibited)
■ Initial error code (Un\G7891481)
The information when the initial processing is completed with an error is stored.
• 1 or more: Initialization abnormal code
• 0: In initial processing or initial normal completion
Receive buffer status storage area (Receive buffer status)
■ Receive buffer status storage area (Receive buffer status) (Un\G7891486)
The receive buffer status is stored.
• 1: Receive buffer full
• 0: Receive buffer not full
PLCopen motion control FB mode/Simple Motion mode
■ PLCopen motion control FB mode/Simple Motion mode (Un\G16252849)
The operation mode is stored.
• 0: PLCopen motion control FB mode
• 1: Simple Motion mode