Mitsubishi Electric MELSEC iQ-R Series User Manual page 151

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

"CC-Link IE TSN/CC-Link IE Field Diagnostics" window
Network map
In this manual, "Authentication Class" is written as "CC-Link IE TSN Class".
Item
Select
Module
Diagnostics
[Change Module]
Destination
button
Select Station
Monitor
[Start Monitoring]
Status
button
[Stop Monitoring]
button
[Update] button
[Legend] button
St. Info
Description
The Motion module under diagnostics is displayed.
Allows to change the target Motion module when multiple Motion module are mounted.
Selects the station No. of the station to be diagnosed.
A station to be diagnosed can also be selected by clicking the module icon displayed in the network map.
Starts monitoring the CC-Link IE TSN/CC-Link IE Field diagnostics.
Stops monitoring the CC-Link IE TSN/CC-Link IE Field diagnostics.
If the actual network configuration and network map of the "CC-Link IE TSN/CC-Link IE Field Diagnostics" window are
inconsistent, the network map update is executed so they are matched. A data link error may momentarily occur in all
the stations and outputs of the connected device stations may turn off since all stations on the network will be
reconnected when executing the network map update. Set output data if needed.
Displays the meaning of icons displayed in the "CC-Link IE TSN/CC-Link IE Field Diagnostics" window.
The display name of the device station can be selected from "By Device Name", "By Station Type", "By Model Name",
or "By IP Address".
"By Device Name" displays the information entered in "Alias" of "Network Configuration Settings" under "Basic
Settings". The station type is displayed when the "Alias" is not entered.
4 TROUBLESHOOTING
4.3 Checking the Network Status