2.5

"CC-Link IE TSN Configuration" Window

Perform the parameter setting of device stations, the detection of connected/disconnected devices, or others.
Navigation window  "Parameter"  "Module Information"  Target module  Module Parameter (Network)  "Basic
Settings"  "Network Configuration Settings"  <Detailed Setting>

Parameter setting of a device station

Set parameters of device stations (the number of points and assignment of link devices) in the master station.
1.
Select the module in "Module List" and drag it to the list of stations or the network map.
List of stations
Network map
2.
Set the required items.
3.
Check the system configuration.
[CC-Link IE TSN Configuration]  [Check]  [System Configuration]
When a warning or error is displayed on the "Output" window, refer to the following.
MELSOFT Navigator Message No.
4.
Select [Close with Reflecting the Setting] and close the "CC-Link IE TSN Configuration" window.
Setting items
• Simple Display: Click the [Simple Display] button to display a narrow portion of items. Use for operation with default settings
or the minimum required settings. (Default)
• Detailed Display: Click the [Detailed display] button to display all items.
Simple
Detailed
display
display
Mode Setting
Assignment
Method
2 PARAMETER SETTINGS
112
2.5 "CC-Link IE TSN Configuration" Window
Drag and drop the text.
Description
The setting of "Module Operation Mode" is displayed.
For details on the setting, refer to the following.
• Module Operation Mode: Page 110 Module Operation Mode
Select a link device assignment method.
• Points/Start: Enter the Nos. of points and start Nos. of link devices.
• Start/End: Enter the start and end Nos.of link devices.
■When the GX Works3 version is "1.085P" or later
• When selecting Points/Start, only points and start can be inputted, and end will
be calculated automatically and displayed.
• When selecting Start/End, only start and end can be inputted, and points will be
calculated automatically and displayed.
■When the GX Works3 version is earlier than "1.085P".
• Select "Points/Start" for the motion control station.
Setting range
• Points/Start
• Start/End
(Default: Points/Start)