HM 1000/1250
Left
2) Adjusting the distance
① Perform the pallet clamping in manual
operation.
② Perform the "Arm 1 Hook Advance" in
manual operation.
③ Then, perform the pallet unclamping
manually back again.
④ Use the APC distance bolt to fit the pallet
hook with the APC hook.
3) Overall adjustment
When you are near completing the adjustment
of height, position and distance, move the
pallet to APC and install the level on the pallet
deck. When the level is fit finally, repeat the
steps above to make the final correction on the
height, position and distance of APC.
84
Right
Gap A
Gap A
Gap B
Left
Gap B
HM1000ISE99
Right
Distance Bolt