HM 1000/1250
5. Assembling the table
1) When the curvic coupling is fixed completely, use the air tool to blow off all dust and
impurities from both upper and lower curvic couplings. Refer to "2. Assembling the table
(pallet base) temporarily" above to assemble the table.
2) If the table settles down with no problem, check the table bolt places if they are aligned
properly. If not, insert two bolts into the cylinder cap as shown and use the pipe to rotate
the cylinder so that it fits into the bolt holes. Then, tighten the table bolts.
▪ 12-BB16×60
Cylinder
Cap
3) Lift up C12051171A clamp plate and put it down on the table in the right direction with
care. Then, tighten the bolts.
▪ 6-BB16×60
HM1000ISE99
12-Table
Fixing Bolt
Clamp Plate
Fixing Bolt
67