Squareness In Division Of Index Table - Doosan HM 1000 Installation Manual

Hide thumbs Also See for HM 1000:
Table of Contents

Advertisement

HM 1000/1250

10.7 Squareness in division of index table

1) How to measure
(1) Place the square horizontally on the pallet
deck. While moving the X axis, correct the
parallelism between square and X axis.
(2) While indexing the B axis, perform the
clamping so that the square should not
move.
(3) While indexing the B axis totally 4 times,
one for each 90 degrees, measure the
parallelism totally 4 times accordingly. The
greatest difference is the measurement.
▪ Tolerance: 0.012mm/300mm
2) Correction
As the angle division of the index table is performed using the precise curvic coupling, it
is unlikely to make an error. However, if you encounter a significant error, that's because
the curvic coupling inside the table is contaminated with dust and impurities, or it is
defective, damaged, or worn out. If this is the case, clean inside the table or replace the
curvic coupling with a new one.
58
Pallet
Locating
Cup
Liner
Fixing Bolt
Locating
Pin
90˚ Index
X axis
HM1000ISE99
Liner

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hm 1250