Temporary Installation Of The Table Bed (X-Axis Bed) Assembly - Doosan HM 1000 Installation Manual

Hide thumbs Also See for HM 1000:
Table of Contents

Advertisement

HM 1000/1250

4.2 Temporary installation of the table bed (X-axis bed) assembly

1) Make preparations for temporary installation by
referring to the "Temporary installation of the
column bed (X-axis bed) assembly" section
above. Lift up the table bed assembly with the
crane or forklift and move it to the temporary
installation site.
▪ Weight: Approx. 7 tons
2) Install the foundation components into the bed.
※ If you are using the crane to lift up the bed, prop up the bed with a strong support for
your safety.
① Insert the bush in the level bolt that has already been installed on the bed.
② With its longer end upward, insert the stud bolt through the level bolt and bush, and
then insert M20 plain washer. Then, tighten the nut.
③ Fit the level block from below and install the anchor.
▪ Insert the stud bolt into the anchor to the possible end.
④ Tighten up the nut while holding the anchor.
⑤ Make a gap of 8∼10mm between level block and bottom of the bed (note that they
should align with each other), and tighten up the level-bolt fixing nut.
Stud Bolt
Plain
Washer
Level-bolt
Fixing Nut
Level Block
3) Place the block under the temporary bolt site of
the bed, and put down the table bed in the right
position.
20
Nut
Bush
Level
Bolt
Anchor
HM1000ISE99
Temporary
Bolt
Block
Level-bolt
Fixing Nut

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hm 1250

Table of Contents