5) If the measurement falls below the target,
tighten up the bolts (2-BB10×35).
4. Setting the table precision
1) Refer to "1 Disassembling the table" above to disassemble the table in sequence.
2) Tighten the curvic coupling bolts (12-BB16×40)
evenly, one by one diagonally, until they are
tightened up.
3) Perform the reaming of the taper pin place
using 13mm taper reamer and insert a new pin.
▪ 2-TPB13×50
4) Insert the plug (FPS-S3/4) into the taper pin place.
※ The plug should not protrude from the coupling.