H3C SR6604-X Manual
Hide thumbs Also See for SR6604-X:

Advertisement

Quick Links

H3C SR6604-X/SR6608-X/SR6616-X
Routers
Hardware Information and Specifications
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 6W100-20230508

Advertisement

Table of Contents
loading

Summary of Contents for H3C SR6604-X

  • Page 1 H3C SR6604-X/SR6608-X/SR6616-X Routers Hardware Information and Specifications New H3C Technologies Co., Ltd. http://www.h3c.com Document version: 6W100-20230508...
  • Page 2 The information in this document is subject to change without notice. All contents in this document, including statements, information, and recommendations, are believed to be accurate, but they are presented without warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3 Preface The H3C SR6604-X/SR6608-X/SR6616-X Routers Hardware Information and Specifications contains the following sections: • Chassis views and technical specifications. • Removable component views and technical specifications. • LEDs. • Slot arrangement and interface numbering. This preface includes the following topics about the documentation: •...
  • Page 4 GUI conventions Convention Description Window names, button names, field names, and menu items are in Boldface. For Boldface example, the New User window opens; click OK. Multi-level menus are separated by angle brackets. For example, File > Create > > Folder.
  • Page 5 It is normal that the port numbers, sample output, screenshots, and other information in the examples differ from what you have on your device. Documentation feedback You can e-mail your comments about product documentation to info@h3c.com. We appreciate your comments.
  • Page 6: Table Of Contents

    Contents 1 Chassis views and technical specifications ·············································· 1-1 Chassis views ················································································································································· 1-1 SR6604-X ················································································································································ 1-1 SR6608-X ················································································································································ 1-2 SR6616-X ················································································································································ 1-4 Dimensions and weights ································································································································· 1-5 Power consumption········································································································································· 1-6...
  • Page 7: Chassis Views And Technical Specifications

    Do not use the rear cover handle when you move the router chassis. This handle is designed to help you remove the rear cover and cannot support the chassis weight. SR6604-X Figure1-1 SR6604-X front view (1) MPU slots (Slot 0 and Slot 1) (2) Fan tray...
  • Page 8: Sr6608-X

    Figure1-2 SR6604-X rear view (1) Rear cover handle (2) Chassis handle (3) Grounding screw and sign (4) Air vents SR6608-X Figure1-3 SR6608-X front view (1) MPU slots (Slot 0 and Slot 1) (2) Fan tray (3) Power module slots (4) LPU or switching fabric module slots (Slot 2 to Slot 5)
  • Page 9 Figure1-4 SR6608-X rear view (1) Rear cover handle (2) Chassis handle (3) Grounding screw and sign (4) Air vents...
  • Page 10: Sr6616-X

    SR6616-X Figure1-5 SR6616-X front view (1) Fan tray (2) Cable management bracket (3) Switching fabric module or LPU slots (Slot 0 to Slot 3 and Slot 6 to Slot 9) (4) MPU slots (Slot 4 and Slot 5) (5) Air inlet vents (An optional air filter can be installed.) (6) Power module slots...
  • Page 11: Dimensions And Weights

    (3) Rear cover handle (4) Grounding screw and sign (5) Power module air exhaust vents Dimensions and weights Table1-1 Router dimensions and weights Item SR6604-X SR6608-X SR6616-X 886 mm (34.88 in, 20 Height (H) 220 mm (8.66 in, 5 RU) 308 mm (12.13 in, 7 RU)
  • Page 12: Power Consumption

    Model Net weight Dimensions (H × W × D) SFE-X1 3.25 kg (7.16 lb) 45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in) FIP-110 3.25 kg (7.16 lb) 45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in) FIP-210 3.35 kg (7.39 lb) 45 ×...
  • Page 13 Table1-4 Fan tray power consumption Model Power consumption RT-FAN-6604-X 40.5 W to 82 W RT-FAN-6608-X 20.20 W to 109 W RT-FAN-6616-X 65.46 W to 262.8 W...
  • Page 14 Contents 2 Removable components ·········································································· 2-1 MPUs ······························································································································································ 2-1 RSE-X2 front panel ································································································································· 2-1 RSE-X2 specifications ····························································································································· 2-1 Components ············································································································································ 2-2 Switching fabric module ·································································································································· 2-4 SFE-X1 front panel ·································································································································· 2-4 SFE-X1 specifications ····························································································································· 2-4 LPUs ······························································································································································· 2-5 FIP-110 ··················································································································································· 2-5 FIP-210 ···················································································································································...
  • Page 15: Removable Components

    Removable components MPUs The RSE-X2 and RSE-X3 are supported by the H3C SR6604-X, SR6608-X, and SR6616-X routers. The RSE-X2 and RSE-X3 are similar in appearance and technical specifications. The following uses an RSE-X2 as an example. For MPU and LPU compatibility, see "Hardware compatibility...
  • Page 16: Components

    CF card CAUTION: Use CF cards provided by H3C only. The router might be incompatible with other CF cards. A compact flash (CF) card stores logs, system software image files, and configuration files. The router is equipped with a built-in CF card, which is identified with cfa0. In addition, the router provides an external CF card slot to expand the storage space.
  • Page 17 For more information, see H3C SR6604-X/SR6608-X/SR6616-X Routers Installation Guide. Table2-2 AUX port specifications Item Specification Connector RJ-45 Compliant standard Asynchronous EIA/TIA-232 Baud rate 9600 bps (default) to 115200 bps Connects to the serial port of a local PC or to a remote PC through dialup...
  • Page 18: Switching Fabric Module

    (at 1 Hz) after the system is booted and operates correctly. Switching fabric module The SFE-X1 is specially designed for the SR6600-X by H3C to improve the router's switching capability. An SR6600-X supports switching fabric modules only when an RSE-X2 MPU is installed.
  • Page 19: Lpus

    • As from the ESS 7821P09 software version, the router does not support the FIP-600 modules. • Use transceiver modules for the LPUs provided by H3C only. The router might be incompatible with transceiver modules from other vendors. The system generates an alarm when a transceiver module from another vendor is installed.
  • Page 20 1000 Mbps, full duplex Available interface modules Table2-7 Maximum number of MIMs supported by routers fully configured with FIP-110 modules FIP/Interface module SR6604-X SR6608-X SR6616-X FIP-110 FIP-210 The FIP-210 provides two combo interfaces. It can hold two HIMs, two MIMs, or a mix of a HIM and...
  • Page 21 Specifications of combo interfaces on the FIP-210 and the FIP-110 are the same. For more information, see Table2-5 and Table2-6. Available interface modules Table2-8 Maximum number of MIMs and HIMs supported by routers fully configured with FIP-210 modules FIP/Interface module SR6604-X SR6608-X SR6616-X FIP-210...
  • Page 22 FIP-240 The FIP-240 provides two combo interfaces. It supports HIMs, MIMs, or a mix of HIMs and MIMs. Front panel Figure2-5 FIP-240 front panel (1) Slot 4 (2) Slot 3 (3) Combo interface 1 (4) Combo interface 0 (5) Slot 1 (6) Slot 2 Technical specifications Item...
  • Page 23: Fip-240

    Available interface modules Table2-9 Maximum number of MIMs and HIMs supported by routers fully configured with FIP-240 modules FIP/Interface module SR6604-X SR6608-X SR6616-X FIP-240 4 (8 half-height HIMs) 8 (16 half-height HIMs) 16 (32 half-height HIMs) FIP-300 The FIP-300 supports HIMs and MIMs, and it provides 12 combo interfaces.
  • Page 24: Fip-300

    Table2-6. Available interface modules Table2-10 Maximum number of MIMs and HIMs supported by routers fully configured with FIP-300 modules FIP/Interface module SR6604-X SR6608-X SR6616-X FIP-300 FIP-310 The FIP-310 supports HIMs and MIM, and it provides 4 combo interfaces and 2 SFP ports.
  • Page 25: Fip-600

    802.3ae Operating mode 10 Gbps (full duplex) Available interface modules Table2-12 Maximum number of MIM and HIMs supported by routers fully configured with FIP-310 modules FIP/Interface module SR6604-X SR6608-X SR6616-X FIP-310 FIP-600 Front panel Figure2-8 FIP-600 front panel (1) Combo interface 1...
  • Page 26 Table2-6. Available interface modules Table2-13 Maximum number of HIMs supported by routers fully configured with FIP-600 modules FIP/Interface module SR6604-X SR6608-X SR6616-X FIP-600 FIP-680 The FIP-680 provides 4 SFP+ ports, 12 SFP ports, and 8 copper GE ports. It supports a maximum of two MICs.
  • Page 27 (1) Interface module slot (2) 10GBASE-R-SFP+ ports (4 in total) (3) 1000BASE-X-SFP ports (12 in total) (4) 10/100/1000BASE-T copper Ethernet ports (8 in total) (5) Module status LED (RUN) (6) 10/100/1000BASE-T copper Ethernet port status LED Technical specifications Item Specification •...
  • Page 28: Fip-680

    1000 Mbps Full duplex, auto-negotiation Available interface modules Table2-17 Maximum number of MICs supported by routers fully configured with FIP-680 modules FIP/Interface module SR6604-X SR6608-X SR6616-X FIP-680 SAP-48GBE Front panel Figure2-10 SAP-48GBE front panel (1) LEDs for GE ports 0 to 47...
  • Page 29: Sap-24Gbp

    Item Specification Supporting 10/100/1000 Mbps autosensing. All ports support Layer 3 routing and high-perform Layer 2 switching functions. Hot swapping Supported Fixed Ethernet port specifications Specifications of the SAP-48GBE fixed Ethernet ports and the FIP-110 fiber combo ports are the same.
  • Page 30: Sap-48Gbp

    SAP-48GBP Front panel Figure2-12 SAP-48GBP front panel (1) SFP ports 0 to 47 (2) SAP module status LED (RUN) (3) LEDs for SFP ports 0 to 47 (4) Ejector lever (5) Captive screw Technical specifications Item Specification • Default—Two 1-GB DDR2 SDRAMs •...
  • Page 31: Sap-20Ge2Xp

    Technical specifications Item Specification • Default—Two 2-GB DDR3 SDRAMs • Maximum—Two 2-GB DDR3 SDRAMs Memory type and size The SDRAMs must be used in pairs and must be the same size. NVRAM 128 KB Fixed Ethernet ports (SFP+) 10G Ethernet ports Hot swapping Supported Fixed Ethernet port specifications...
  • Page 32 Item Specification 10G SFP+ ports Hot swapping Supported. Fixed Ethernet port specifications Table2-19 SFP port specifications Item Specification Connector type Transceiver module type Network synchronization Supported 1588v2.2 protocol Supported Interface standards 802.3, 802.3u, and 802.3ab Operating mode 1000 Mbps, full duplex Table2-20 Combo copper port specifications Item Specification...
  • Page 33: Sap-28Ge

    SAP-28GE Front panel Figure2-15 SAP-28GE front panel (1) SFP ports (GE0 to GE15) (2) Combo interfaces (GE16 to GE27) (3) Operating status LED (RUN) Technical specifications Item Specification • Default—Two 2-GB DDR3 SDRAMs. • Maximum—Four 2-GB DDR3 SDRAMs. Memory type and size The SDRAMs must be used in pairs and must be the same size.
  • Page 34: Spes/Oaps

    For the combo fiber port specifications, see Table2-22. SPEs/OAPs H3C SR6604-X, SR6608-X, and SR6616-X routers support the service processing engine (SPE). Based on the open application platform (OAP), the SPE can provide multiple services. For more information about the SPE and OAP, see relevant datasheet.
  • Page 35: Power Modules

    SPE-SSL-200 Power modules The SR6604-X, SR6608-X, and SR6616-X routers support hot-swappable AC and DC power modules, but an AC and a DC power module cannot work together. You can install one or, for redundancy, multiple power modules, but the power modules in use must have the same specifications.
  • Page 36: Dc Power Modules

    PSR1200-A Figure2-17 PSR1200-A view (1) AC-input power receptacle (2) Power switch (3) Handle (4) Power module status LED Table2-27 PSR1200-A specifications Item Remarks Rated input voltage 100 VAC to 240 VAC @ 50 or 60 Hz Maximum input current 16 A Maximum power 1213 W DC power modules...
  • Page 37 Table2-28 PSR650-D specifications Item Remarks Rated input voltage –48 VDC to –60 VDC Maximum input current 25 A Maximum power 650 W PSR1200-D Figure2-19 PSR1200-D view (1) Power module connector (2) Power switch (3) Handle (4) Power module status LED Table2-29 PSR1200-D specifications Item Remarks...
  • Page 38: Fan Trays

    Fan trays Figure2-20 Fan tray for the SR6604-X Figure2-21 Fan tray for the SR6608-X (1) Fan (2) Fan tray status LED (RUN) (3) Alarm LED (ALM) (4) Handle (5) Rotating blade hazard label 2-24...
  • Page 39: Hims/Mims/Mics

    NOTE: The fan tray structure for the SR6604-X is similar with the fan tray structure for the SR6608-X. Figure2-22 Fan tray for the SR6616-X (1) Fan (2) Alarm LED (ALM) (3) Fan tray status LED (RUN) (4) Fan tray release button...
  • Page 40: Power Strip With Lightning Protection

    • Core-ground ≤ 350 V protector For how to install the lightning protector for a port, see H3C SR6604-X/SR6608-X/SR6616-X Routers Installation Guide. Power strip with lightning protection If part of the AC power line is routed outdoors, use a power strip with lightning protection to connect the AC power cord of the router to the AC power line to protect the router from being damaged by lightning strikes.
  • Page 41 Contents 3 LEDs ········································································································ 3-1 MPU and switching fabric module LEDs ········································································································· 3-1 LPU LEDs ······················································································································································· 3-3 FIP LEDs ················································································································································· 3-3 SAP LEDs ··············································································································································· 3-7 SPE LEDs ····················································································································································· 3-11 HIM/MIM/MIC LEDs ······································································································································ 3-11 Power module LEDs ····································································································································· 3-12 Fan LEDs ······················································································································································ 3-13...
  • Page 42: Leds

    LEDs H3C SR6604-X, SR6608-X, and SR6616-X routers provide LEDs for FRUs to indicate their operating status. MPU and switching fabric module LEDs The LEDs for the RSE-X2 and RSE-X3 are the same. The following uses the RSE-X2 as an example.
  • Page 43 Status Description The MPU is in standby state. Steady on The MPU is in active state. (green) No power input is available, or the MPU has failed. Slow flashing The MPU is operating correctly. (1 Hz) The system software is being loaded. CAUTION: (green) Fast flashing...
  • Page 44: Lpu Leds

    LPU LEDs FIP LEDs FIP-110/FIP-210/FIP-240/FIP-600 LEDs Figure3-3 FIP-110 status LED Figure3-4 FIP-210 status LED Figure3-5 FIP-240 status LED...
  • Page 45 Figure3-6 FIP-600 status LED Table3-3 FIP-110/FIP-210/FIP-240/FIP-600 LED description Status Description No link is present. Steady green A 1000 Mbps link is present. Status LEDs Flashing green Data is being received or transmitted at 1000 Mbps. for GE 0 to GE 1 Steady yellow A 10/100 Mbps link is present.
  • Page 46 Table3-4 FIP-300 LED description Status Description No link is present. Steady green A 1000 Mbps link is present. Status LEDs Flashing green Data is being received or transmitted at 1000 Mbps. for GE 0 to GE 11 Steady yellow A 10/100 Mbps link is present. (yellow/green) Flashing Data is being received or transmitted at 10/100 Mbps.
  • Page 47 Status Description No link is present. Steady green A 1000 Mbps link is present. Status LEDs for SFP 0 to Data is being received or transmitted at 1000 Flashing green SFP 3 Mbps. (yellow/green) Steady yellow The transceiver module has failed the POST. No power input is available or the FIP has failed.
  • Page 48: Sap Leds

    Status Description No power input is available or the FIP has failed. Slow flashing (1 Hz) The FIP is operating correctly. Module status System software is being loaded. (green) To avoid damage to the FIP, never power off the (RUN) Fast flashing (8 Hz) device or hot-swap the FIP while the system software is being loaded.
  • Page 49 Table3-8 SAP-24GBP LED description Status Description No power input is available or the SAP-24GBP has failed. Slow flashing (1 Hz) The SAP-24GBP is operating correctly. System software is being loaded or the SAP-24GBP is not operating. (green) CAUTION: Fast flashing (8 Hz) To avoid hardware damage, do not power off the router, or insert or remove the SAP-24GBP when system software is being loaded.
  • Page 50 Figure3-13 SAP-4EXP LEDs Table3-10 SAP-4EXP LED description Status Description No power input is available or the SAP-4EXP has failed. Slow flashing (1 Hz) The SAP-4EXP is operating correctly. System software is being loaded or the SAP-4EXP is not operating. (green) CAUTION: Fast flashing (8 Hz) To avoid hardware damage, do not power off the...
  • Page 51 Status Description No link is present. Status LEDs Steady green A 10 Gbps link is present. for SFP+ port 0 and Flashing green Data is being received or transmitted at 10 Gbps. (yellow/green) SFP+ port 1 Steady yellow The transceiver module has failed to be detected. No link is present.
  • Page 52: Spe Leds

    A 100 Mbps link is present. GE15 Flashing yellow Data is being received or transmitted at 100 Mbps. SPE LEDs For SPE LED description, see the corresponding datasheet. HIM/MIM/MIC LEDs For HIM/MIM/MIC LED description, see H3C SR6600/SR6600-X Routers Interface Module Guide. 3-11...
  • Page 53: Power Module Leds

    Power module LEDs Figure3-16 PSR650-A AC power module LED Figure3-17 PSR1200-A AC power module LED Figure3-18 PSR650-D DC power module LED Figure3-19 PSR1200-D DC power module LED Table3-13 AC/DC power LED description Status Description Steady green The power module is operating correctly. Power LED Steady red The power module is faulty.
  • Page 54: Fan Leds

    Fan LEDs Figure3-20 Fan LEDs for the SR6604-X Figure3-21 Fan LEDs for the SR6608-X 3-13...
  • Page 55 Figure3-22 Fan LEDs for the SR6616-X Table3-14 Fan LED description Status Description The system is powered off or the fan tray is faulty. Steady on The fan is operating correctly. (green) The fan is operating correctly. Steady on The fan is faulty. (red) 3-14...
  • Page 56 Contents 4 Slot arrangement and interface numbering ·············································· 4-1 Slot arrangement············································································································································· 4-1 Available slots for cards ·································································································································· 4-2 Numbering interfaces ······································································································································ 4-3 Examples ························································································································································ 4-3 Example 1 ··············································································································································· 4-3 Example 2 ··············································································································································· 4-3...
  • Page 57: Slot Arrangement And Interface Numbering

    Slot arrangement The router provides many types of interfaces, such as console, AUX, GigabitEthernet, serial (synchronous), POS, and E1 ports. This chapter describes how these interfaces are numbered. Figure4-1 Slot arrangement on the SR6604-X Figure4-2 Slot arrangement on the SR6608-X...
  • Page 58: Available Slots For Cards

    Figure4-3, the blue and dark numbers represent slot numbers of the cards and power modules, respectively. Available slots for cards Table4-1 Available slots for cards Card SR6604-X SR6608-X SR6616-X RSE-X2/RSE-X3 (supporting 1+1 Slot 0 and Slot 1 Slot 0 and Slot 1...
  • Page 59: Examples

    Numbering interfaces Before installing a HIM/MIM/MIC, you must install a FIP. The interfaces of the router are numbered in the form of interface-type X/Y/Z, Where, • interface-type—Type of the interface such as GE port and serial port. • X—Number of the slot where the FIP/SAP resides (for example, blue numbers in Figure4-1 through Figure4-3).

This manual is also suitable for:

Sr6608-xSr6616-x

Table of Contents