Installing A Fip Module And An Air Deflector; Installing A Fip Module - H3C SR6604 Installation Manual

Hide thumbs Also See for SR6604:
Table of Contents

Advertisement

Installing a FIP module and an air deflector

Installing a FIP module

IMPORTANT:
FIP-10 and FIP-20 can operate correctly only on a router installed with an MCP.
The router supports hot swapping of FIP modules.
The installation procedure is similar for FIPs. The following procedure installs a FIP-210.
To install a FIP module:
1.
Locate the slot to install the FIP module.
2.
Loosen the captive screws on the filler panel, and then remove the filler panel.
3.
Use even pressure to gently push the FIP module into the slot along the slide rails until
positioning pins on the backplane are seated in the positioning holes, and then push the ejector
levers inward to lock the FIP module in position.
If you encounter a resistance when pushing a FIP module into slot, remove the filler panels from
the left and right slots and then install the FIP module. After the FIP module is installed, reinstall
the removed filler panels to prevent dust from entering the chassis.
Figure2-15 Inserting a FIP module
4.
Fasten the captive screws on the FIP module.
5.
Observe the RUN LED on the FIP to verify that the FIP module is installed correctly.
After the router is powered on, the RUN LED on the FIP flashes green once and then fast
flashes (at 8 Hz) until the application software is loaded. When the RUN LED flashes green at 1
Hz, the FIP is operating correctly.
For the FIP LED descriptions, see H3C SR6604[6608] Routers Hardware Information and
Specifications.
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr6608

Table of Contents