(Optional) Installing an air deflector

For a FIP-660, if a service module slot adjacent to the FIP-660 is empty, install an air deflector over
the slot.
To install an air deflector:
1.
Locate the service module slot to install the air deflector.
2.
Loosen the captive screws on the filler panel, and then remove the filler panel.
3.
Gently push the air deflector into the service slot along the slide rails until it snaps into place.
4.
Fasten the captive screws on the air deflector.
Figure2-16 Installing an air deflector
2

Installing a SAP/OAP/switching fabric module

The router supports hot swapping of SAPs, OAPs, and switching fabric modules.
The installation procedure is similar for SAPs, OAPs, and switching fabric modules. The following
procedure installs a SAP module.
To install a SAP module:
1.
Locate the slot to install the SAP module.
2.
Loosen the captive screws on the filler panel, and then remove the filler panel.
3.
Use even pressure to gently push the SAP module into the slot along the slide rails until
positioning pins on the backplane are seated in the positioning holes, and then push the ejector
levers inward to lock the SAP module in position.