Cooling System Failure - H3C SR6604 Installation Manual

Hide thumbs Also See for SR6604:
Table of Contents

Advertisement

|<7> BootWare Operation Menu
|<8> Skip Authentication for Console Login
|<9> Storage Device Operation
|<0> Reboot
============================================================================
Ctrl+Z: Access EXTENDED ASSISTANT MENU
Ctrl+F: Format File System
Ctrl+C: Display Copyright
Enter your choice(0-9): 5
2.
At the prompt for confirmation, enter
The router deletes its main and backup next-startup configuration files and restores the
factory-default configuration.
The current mode is no password recovery. The configuration files will be
deleted, and the system will start up with factory defaults, Are you sure to
continue?[Y/N]Y
Setting...Done.
3.
When the EXTEND-BOOTWARE menu appears again, enter
The router starts up with the factory-default configuration.
4.
Configure a new console login password (see
5.
To make the settings take effect after a reboot, save the running configuration to the
next-startup configuration file.
[sysname] save

Cooling system failure

Symptom
When the environmental temperature of a module reaches or exceeds the high temperature
threshold, the fans rotate at full speed, and the following information appears on the configuration
terminal:
%Might
4 19:37:29:945 2017 H3C DRVMSG/3/Temp2High:
Environment temperature too high in Slot 5, index is 0.
When the CPU temperature of a module reaches or exceeds the high temperature threshold, the
fans rotate at full speed, and the following information appears on the configuration terminal:
%Might
4 19:37:29:945 2017 H3C DRVMSG/3/Temp2High:
CPU temperature too high in Slot 5, index is 0.
When the environmental temperature of a module reaches or exceeds the critical temperature
threshold, the fans rotate at full speed, and the following information appears on the configuration
terminal repeatedly:
%Might
4 19:37:54:945 2017 H3C DRVMSG/3/TempCritical:
Environment temperature critical in Slot 5, index is 0.
When the CPU temperature of a module reaches or exceeds the critical temperature threshold, the
fans rotate at full speed, and the following information appears on the configuration terminal
repeatedly:
%Might
4 19:37:54:945 2017 H3C DRVMSG/3/TempCritical:
CPU temperature critical in Slot 5, index is 0.
When the environmental or CPU temperature of a module exceeds the critical temperature threshold,
the ALM LED of the MPU is red.
.