Prerequisites
Before installing this option, be sure you have the following:
The components included with the hardware option kit
Procedure
1.
Observe the following alert:
IMPORTANT: After removing a high-performance (dual-rotor) fan, install or replace the fan within 60
seconds. Otherwise, the server will shut down gracefully.
2.
Power down the server (Power down the server on page 31).
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Do one of the following:
a. Extend the server from the rack (Extend the server from the rack on page 31).
b. Remove the server from the rack (Remove the server from the rack on page 32).
5.
Remove the access panel (Remove the access panel on page 32).
6.
Remove all standard fans from the fan bays.
7.
Remove fan blanks from the fan bays, if installed.