HPE ProLiant DX360 Gen10 User Manual page 53

Table of Contents

Advertisement

a. Extend the server from the rack (Extend the server from the rack on page 31).
b. Remove the server from the rack (Remove the server from the rack on page 32).
4.
Remove the access panel (Remove the access panel on page 32).
5.
Locate any NVDIMMs already installed in the server.
6.
Verify that all LEDs on any installed NVDIMMs are off.
7.
Install the NVDIMM.
8.
Install and connect the HPE Smart Storage Battery, if it is not already installed.
Installing an energy pack in 8 SFF and 4 LFF configurations on page 135
Installing an energy pack in the 10 SFF SAS/SATA/NVMe Combo backplane configuration on page 132
9.
Install any components removed to access the DIMM slots and the HPE Smart Storage Battery.
10. Install the access panel.
11. Slide or install the server into the rack.
12. If removed, reconnect all power cables.
13. Power up the server.
14. If required, sanitize the NVDIMM-Ns. For more information, see NVDIMM sanitization on page 54.
Configuring the server for NVDIMMs
After installing NVDIMMs, configure the server for NVDIMMs. For information on configuring settings for NVDIMMs, see
the HPE 16GB NVDIMM User Guide on the Hewlett Packard Enterprise website (http://www.hpe.com/info/nvdimm-
docs).
The server can be configured for NVDIMMs using either of the following:
Hardware options installation
53

Advertisement

Table of Contents
loading

Table of Contents