ENGINE ELECTRICS
Removing, installing the charge air pressure sensor EDC
(1) Charge air pressure sensor
Technical data
Charge air pressure sensor mounting bolt.............. M6x16 ................................................................ 9 Nm
Important information
WARNING
Component damage due to incorrectly tightened screw/bolt connections
• If impact wrenches are used, these may only be used for pretightening to max. 50% of the
specied tightening torque
• Final tightening must always be performed manually using a torque wrench
WARNING
Restricted operation due to incorrect entries in the fault memory
• Before removing switches or sensors, read out and document the fault memory
• Always install switches and sensors with new O-rings or sealing rings
• After installing switches or sensors, read out the fault memory and, if necessary, delete it
AE6 3st edition
ENGINE ELECTRICS
33