User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software

storm-control flowcontrol

This command enables 802.3x flow control for the switch.
Note: This command only applies to full-duplex mode ports.
Default
Format
Mode

no storm-control flowcontrol

This command disables 802.3x flow control for the switch.
Note: This command only applies to full-duplex mode ports.
Format
Mode

vlan

This command creates a new VLAN and assigns it an ID. The ID is a valid VLAN identification
number (ID 1 is reserved for the default VLAN). VLAN range is 2-4094.
Format
Mode

no vlan

This command deletes an existing VLAN. The ID is a valid VLAN identification number (ID 1 is
reserved for the default VLAN). VLAN range is 2-4094.
Format
Mode
Switching Commands
Disabled
storm-control flowcontrol
Global Config
no storm-control flowcontrol
Global Config
vlan <2-4094>
VLAN database
no vlan <2-4094>
VLAN database