Dot1X Re-Authentication; No Dot1X Re-Authentication; Dot1X System-Auth-Control; No Dot1X System-Auth-Control - NETGEAR ProSafe GSM7212 User Manual

Layer 2 managed switch software
Hide thumbs Also See for ProSafe GSM7212:
Table of Contents

Advertisement

User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software

dot1x re-authentication

This command enables re-authentication of the supplicant for the specified port.
Default
Format
Mode

no dot1x re-authentication

This command disables re-authentication of the supplicant for the specified port.
Format
Mode

dot1x system-auth-control

This command is used to enable the dot1x authentication support on the switch. By default, the
authentication support is disabled. While disabled, the dot1x configuration is retained and can be
changed, but is not activated.
Default
Format
Mode

no dot1x system-auth-control

This command is used to disable the dot1x authentication support on the switch.
Format
Mode

dot1x timeout

This command sets the value, in seconds, of the timer used by the authenticator state machine on
this port. Depending on the token used and the value (in seconds) passed, various timeout
configurable parameters are set. The following tokens are supported.
8-98
Disabled
dot1x re-authentication
Config
Interface
no dot1x re-authentication
Interface Config
Disabled
dot1x system-auth-control
Global Config
no dot1x system-auth-control
Global Config
December 2004, 202-10010-02
Switching Commands

Advertisement

Table of Contents