5.3

Analog monitor [G] [B]

The voltage of the analog monitor output may be irregular at power-on.
The status of the servo amplifier, such as the servo motor speed, torque, and bus voltage, can be output with the voltage to
two channels at the same time.
For the MR-J5_-_B_, this function is available only with 1-axis servo amplifiers.

Setting method [G]

Which signal to be output by analog monitor 1 or analog monitor 2 can be selected, and the offset voltage of each analog
monitor can be set using the extension setting parameters in MR Configurator2. The setting range of the offset voltage is -999
mV to 999 mV.
Servo parameter Symbol
PC09.0-1
MOD1
PC09.3
MOD1
PC10.0-1
MOD2
PC10.3
MOD2
PC11
MO1
PC12
MO2

Setting method [B]

Which signal to be output by analog monitor 1 or analog monitor 2 can be selected, and the offset voltage of each analog
monitor can be set using the extension setting parameters in MR Configurator2. The setting range of the offset voltage is -999
mV to 999 mV.
Servo parameter Symbol
PC09.0-1
MOD1
PC10.0-1
MOD2
PC11
MO1
PC12
MO2
5 MONITORING
410
5.3 Analog monitor [G] [B]
Name
Analog monitor 1 output selection
Analog monitor output 1 output
axis selection
Analog monitor 2 output selection
Analog monitor output 2 output
axis selection
Analog monitor 1 offset
Analog monitor 2 offset
Name
Analog monitor 1 output selection
Analog monitor 2 output selection
Analog monitor 1 offset
Analog monitor 2 offset
Outline
Select the signal to be output to analog monitor 1. Refer to the following for
setting values.
Page 411 Setting details [G] [B]
Select the axis to be monitored with analog monitor 1. This servo parameter can
be used with MR-J5W_-_G_.
0: A-axis (initial value)
1: B-axis
2: C-axis
Select the signal to be output to analog monitor 2. Refer to the following for
setting values.
Page 411 Setting details [G] [B]
Select the axis to be monitored with analog monitor 2. This servo parameter can
be used with MR-J5W_-_G_.
0: A-axis (initial value)
1: B-axis
2: C-axis
Set the offset voltage of MO1 (Analog monitor 1).
Initial value: 0 [mV]
Set the offset voltage of MO2 (Analog monitor 2).
Initial value: 0 [mV]
Outline
Select the signal to be output to analog monitor 1. Refer to the following for
setting values.
Page 411 Setting details [G] [B]
Select the signal to be output to analog monitor 2. Refer to the following for
setting values.
Page 411 Setting details [G] [B]
Set the offset voltage of MO1 (Analog monitor 1).
Initial value: 0 [mV]
Set the offset voltage of MO2 (Analog monitor 2).
Initial value: 0 [mV]

Advertisement