Mitsubishi Electric MELSERVO-J5 User Manual page 375

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

Setting method [G] [B]
When [Pr. PC19.4 Output open-phase detection selection] is set to "1" (enabled), the output open-phase detection function
will be enabled.
Servo
Symbol
Name
parameter
PC19.4
*COP6
Output open-phase detection selection
PC19.6
*COP6
Output open phase - Judgment speed
selection
Setting method [A]
When [Pr. PC26.4 Output open-phase detection selection] is set to "1" (enabled), the output open-phase detection function
will be enabled.
Servo
Symbol
Name
parameter
PC26.4
*COP5
Output open-phase detection selection
PC26.6
*COP5
Output open phase - Judgment speed
selection
Outline
Enable or disable the detection of output open-phase detection function.
0: Disabled (initial value)
1: Enabled
Select the judgment speed of the output open-phase detection function.
0: Servo motor speed (initial value)
1: Speed command
In the torque control, set "0" (servo motor speed). When "1" (speed command) is set,
[AL. 139.2 Output open-phase error] does not occur.
Outline
Enable or disable the detection of output open-phase detection function.
0: Disabled (initial value)
1: Enabled
Select the judgment speed of the output open-phase detection function.
0: Servo motor speed (initial value)
1: Speed command
In the torque control, set "0" (servo motor speed). When "1" (speed command) is set,
[AL. 139.2 Output open-phase error] does not occur.
4.20 Disconnection/incorrect wiring detection function
4 APPLICABLE FUNCTIONS
4
373