Mitsubishi Electric MELSERVO-J5 User Manual page 302

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

■Threshold setting for belt tension
Set a threshold to generate [AL. 0F7 Machine diagnosis warning]. When the belt tension estimated value inside the servo
amplifier falls below the belt tension threshold, [AL. 0F7 Machine diagnostic warning] occurs.
[Pr. PF72
Belt tension on installation]
[Pr. PF73
Belt tension when extended]
*1
Belt tension threshold
Servo
Symbol
parameter
PF76
BTS
■Belt tension prediction warning selection setting
To enable belt tension prediction warning, set [Pr. PF71.0 Belt tension deterioration prediction function selection].
Furthermore, when a value other than 0 is set in [Pr. PF72 Belt tension on installation], [Pr. PF73 Belt tension when extended],
[Pr. PF74 Static friction during installation], and [Pr. PF75 Static friction when extended], setting a value other than "0"
(disabled) in [Pr. PF71.0 Belt tension deterioration prediction function selection] will estimate the belt tension.
Servo
Symbol
parameter
PF71.0
BFP
■Belt tension deterioration prediction function
During belt tension prediction, [AL. 0F7 Machine diagnostic warning] occurs when the static friction estimated by the friction
estimation function falls below the threshold. After the occurrence of [AL. 0F7 Machine diagnosis warning], if the static friction
becomes equal to or higher than the threshold value, [AL. 0F7 Machine diagnostic warning] will be canceled.
Static friction
ON
WNG
(Warning)
OFF
4 APPLICABLE FUNCTIONS
300
4.5 Machine diagnosis
Static friction
[Pr. PF75
that triggers
Static friction
a warning
when extended]
Name
Belt tension irregular threshold
Name
Belt tension deterioration prediction function selection
Torque
[Pr. PF74
Static friction
during installation]
Description
Set a threshold to generate [AL. 0F7 Machine diagnosis
warning]. Set this servo parameter as a percentage of [Pr. PF72
Belt tension on installation]. When using the belt diagnosis
function, input a value other than 0.
Initial value: 0 [0.1 %]
Description
Belt tension deterioration prediction function selection
0: Disabled (initial value)
1: Execute only belt tension estimation
2: Belt tension deterioration prediction function enabled
After the equipment goes into actual operation, enable the belt
tension deterioration prediction function.
Time

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5

Table of Contents