Mitsubishi Electric MELSERVO-J5 User Manual page 288

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

*1 Estimated static friction and dynamic friction can be saved by opening the machine diagnostic screen of MR Configurator2.
*2 If the equipment has been operated for less than continuous three hours, or the friction estimation has not finished for the rotation
direction set in [Pr. PF40.5 Static friction failure prediction - Static friction selection], the threshold is not calculated automatically.
■Static friction failure prediction warning setting
Set [Pr. PF34.5 Static friction failure prediction warning selection], and enable the static friction failure prediction warning.
When "1" (static friction threshold automatic setting) is set, the threshold is automatically calculated inside the servo amplifier.
When "2" (static friction threshold manual setting) is set, set the threshold with servo parameter.
Servo
Symbol
parameter
PF34.5
*MFP
■Setting "Failure prediction - Servo motor total travel distance"
When using the automatic threshold setting, set the Failure prediction - Servo motor total travel distance in [Pr. PF41 Failure
prediction - Servo motor total travel distance].
If the machine total travel distance is smaller than the Failure prediction - Servo motor total travel distance, the threshold will
not be automatically set from the estimated static friction, assuming that the belt has been initially stretched. Set a machine
total travel distance at which the initial stretch completes in consideration of the Failure prediction - Servo motor total travel
distance by referring to the initial stretch characteristic presented by respective belt manufacturers and the typical drive
pattern of the device. For example, if the Failure prediction - Servo motor total travel distance is to be 8 × 10
[10 rev] in [Pr. PF41 Failure prediction - Servo motor total travel distance].
4 APPLICABLE FUNCTIONS
286
4.5 Machine diagnosis
Name
Static friction failure prediction warning selection
Description
0: Disabled (initial value)
1: Automatic threshold setting
2: Manual threshold setting
3: Threshold reset
5
rev, set "80000"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5

Table of Contents