Mitsubishi Electric MELSERVO-J5 User Manual page 426

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

Data type
Failure prediction status
Friction failure prediction -Threshold
Vibration failure prediction -Threshold
Failure prediction - Preparation progress
Machine total travel distance
Estimated tension value
*1 When warning conditions for 2 to 6 are established at the same time, the smallest number is returned.
*2 Once an estimation finishes even after a warning has occurred, the status will change to "Estimation has finished".
5 MONITORING
424
5.5 Optional data monitor function [B]
Description
The failure prediction status is displayed.
[Bit 0 to 3: Friction failure prediction status]
0:Friction failure prediction disabled
1:During preparation for friction failure prediction
2:During execution of friction failure prediction
3:During friction failure prediction warning
[Bit 4 to 7: Vibration failure prediction status]
0:Vibration failure prediction disabled
1:During preparation for vibration failure prediction
2:During execution of vibration failure prediction
3:During vibration failure prediction warning
[Bit 8 to 11: Total travel distance failure prediction status]
0:Motor total travel distance failure prediction disabled
1:Motor total travel distance failure prediction being executed
2:Motor total travel distance failure prediction at warning
[Bit 12 to 15: Motor total travel distance calculation status]
0:During stop of motor total travel distance calculation
1:During calculation of motor total travel distance
[Bit 16 to 19: Motor total travel distance 2 failure prediction status]
0:Motor total travel distance 2 failure prediction disabled
1:Motor total travel distance 2 failure prediction being executed
2:Motor total travel distance 2 failure prediction at warning
[Bit 20 to 23: Static friction failure prediction status]
0:Static friction failure prediction disabled
1:During preparation for static friction failure prediction
2:During execution of static friction failure prediction
3:During static friction failure prediction warning
[Bit 24 to 27: Belt tension deterioration prediction status]
0:Belt tension deterioration prediction disabled
1:Belt tension deterioration prediction in progress
2:During belt tension deterioration warning
[Bit 28 to 31: Belt tension estimation status]
0:Belt tension estimation in progress
1:Belt tension estimation has finished
7:Belt tension estimation is not set
The threshold used for friction failure prediction is displayed in increments of 0.1 % in relation to the rated torque
as 100 %.
The threshold used for vibration failure prediction is displayed in increments of 0.1 % in relation to the rated
torque as 100 %.
The threshold creation progress used for failure prediction is displayed as a percentage. Creation of the
threshold for failure prediction finishes at 100 %.
The machine total travel distance is displayed in increments of 10 rev.
The estimated tension value used by the belt tension deterioration prediction function is expressed in 0.1 N units

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5

Table of Contents