Mitsubishi Electric MELSERVO-J5 User Manual page 31

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

Index
Sub
Object
60B2h
VAR
Controlword/Statusword
By changing [Controlword (Obj. 6040h)], control commands can be given to the servo amplifier. The control status can also be
checked with [Statusword (Obj. 6041h)].
Some bits of [Controlword (Obj. 6040h)] and [Statusword (Obj. 6041h)] vary depending on the control mode. The bits that vary
depending on the control mode are listed in the following tables.
■Controlword OMS Bit (cst)
Bit
Symbol
4
(reserved)
5
(reserved)
6
(reserved)
8
(reserved)
9
(reserved)
■Statusword OMS Bit (cst)
Bit
Symbol
10
(reserved)
12
Drive follows the command
value
(Target position ignored)
13
(reserved)
Name
Torque offset
Description
The value at reading is undefined. Set "0" when writing.
Description
The value at reading is undefined.
0: [Target torque (Obj. 6071h)] is being discarded.
1: [Target torque (Obj. 6071h)] is being used as a torque control loop input.
The value at reading is undefined.
Description
Torque offset
Unit: 0.1 % (with rated torque being 100 %)